ADD DIF TEMP function:
This function controls the restarting of the additional electrical heater, depending on the specified water
The electrical heater will stop operating when the water temperature reaches the set feed temperature
OUTADD.HEAT function:
The outdoor additional heater setting can be ON or OFF; the factory setting is ON.
When the outdoor electrical heater is selected as ON the heater will automatically start when the ambient
When the outdoor electrical heater is selected as OFF the outdoor heater cannot start automatically.
ADD ENFORCE function:
The enforced additional heater operation can be ON or OFF; the factory setting is ON.
WATER PUMP function:
Press button RIGHT once will change from 0/0 to 3/10, press the button again will change to 3/10, press
again will change to 3/15, press again will change to 3/20, press again will return to 0/0
0/0 means water pump (for heating) will keep running when house or water tank reach setting temperature
in ROOMHEAT 1 and ROOMHEAT2.
3/10 means that under ROOMHEAT 1 and ROOM HEAT 2; if the setting temperature reach and the
compressor stop, the water pumps (for heating) will runs 3 minutes to detect the water temperature,
if no need to keep running the water pump will stop 10 minutes, then runs 3 minutes again to see if need to
restart compressor and keep water pump running.
3/15 means that under ROOMHEAT 1 and ROOM HEAT 2; if the setting temperature reach and the
compressor stop, the water pumps (for heating) will runs 3 minutes to detect the water temperature,
if no need to keep running the water pump will stop 15 minutes, then runs 3 minutes again to see if need to
restart compressor and keep water pump running.
3/20 means that under ROOMHEAT 1 and ROOM HEAT 2; if the setting temperature reach and the
compressor stop, the water pumps (for heating) will runs 3 minutes to detect the water temperature,
if no need to keep running the water pump will stop 20 minutes, then runs 3 minutes again to see if need to
restart compressor and keep water pump running.
ALARM RECORD function:
Selecting this menu item by pressing RIGHT shows the last eight ALARMS, the most recent being displayed
first, i.e. in the topmost line of the display. The date, month, and year will be shown. NOTE: a loss of power
will clear history.
LANGUAGE function:
Either English or French language can be set through this menu item.