IMPORTANT: Adjustment of the ROOM value should only be used for temporary changes of the
indoor temperature.
If you use ROOM value to adjust the heat curve the gradient does not change, meaning it does not become
As a result, the relationship between feed line temperature and outside air temperature will not be affected.
Changing ROOM Value
CURVE
40º
64
56
48
40
32
24
15
5
0
Outside air temperature
the heat curve or the DM value.
Under certain ambient temperatures the time start of compressor is determined by the DM value.
HIGHT STOP
When the outdoor ambient temperature is higher than this setting, the hot water production by the
heat pump to room or water tank will be stopped, having reached the maximum allowable operating
temperature. At this point the circulation pump will be turned off.
LOWT STOP
When the outdoor ambient temperature is lower than this setting, the hot water production by the heat
pump to room or water tank will be stopped, having reached the minimum allowable operating temperature.
At this point the circulation pump will be turned off.
For this reason, the control system includes a function allowing the curve to be adjusted at three outside
18
-5
ºC
44