Eko Warrior ks50-dc Installation And Operating Instructions Manual page 49

Dc inverter series air to water heat pump
Table of Contents

Advertisement

When the cursor is showing against the item, press RIGHT for five seconds to display the information as a
chart showing temperature over the last 60 minutes.
PIPE:
When the cursor is showing against the item, press RIGHT for five seconds to display the information as a
chart showing temperature over the last 60 minutes.
OUT: Displays outdoor ambient temperature.
CMPDIF TEMP: This value determines how much the hot water tank is allowed to cool before heating
This feature prevents room heating from repeatedly stopping while the hot water tank temperature is raised
by the system. This is especially useful when the room heating system is starting up and rooms are cold and
hot water tank temperature is not a priority.
Too large a CMPDIF value will mean that the hot water tank may become colder than required for baths or
showers.
CONSTANT: This value determines when the heating will come back on much like the CMPDIF so if set
FEEDLINE
64
48
32
16
0
-16
60
30
Outside air temperature
All temperature changes registered over the last hour are stored in the control system and can be viewed in
graphical form. This will enable you to monitor changes in the temperature at different points in the system.
When at item WARMWT, ROOM, RETURN, FEED, or PIPE, pressing RIGHT for five seconds will display the
information as a chart covering one hour.
48ºC
NOTE:
During the cmpdif and constant
temperature difference to the set temperature
the compressor will still run at a reduced rate
dependant on demand.
NOTE:
The compressor may still run at a lower
ºC
rate between 48 and 44 in the above example.
48