6
Dimensional drawing & centre of gravity
6 - 1
Dimensional drawing
FUQ71B
Drain connection
location for upper
1
piping
6
z Drain pipe can be raised up to 350mm from the top surface of the product.
Liquid pipe connection - J9.5 flare
1
Gas pipe connection J15.9 flare
2
3
Drain pipe connection V.P.20
4
Air outlet
5
Air suction grille
6
Corner decoration cover
7
Right pipe / wiring connection
8
Rear pipe / wiring connection
9
Pipe through cover
10
Accessory drain elbow
FUQ100-125B
Drain connection
location for upper
piping
z Drain pipe can be raised up to 350mm from the top surface of the product.
Liquid pipe connection - J9.5 flare
1
Gas pipe connection J15.9 flare
2
3
Drain pipe connection V.P.20
4
Air outlet
5
Air suction grille
6
Corner decoration cover
7
Right pipe / wiring connection
8
Rear pipe / wiring connection
9
Pipe through cover
10
Accessory drain elbow
7
• Indoor Units • R-410A • FUQ-BVV1B
Drain connection
location for rear piping
Brand name plate (note 2)
Drain connection
location for rear
piping
Brand name plate (note 2)
• Split Sky Air • Indoor Units
z 1500 mm or
Required space
z 1500 mm
or more
790 Suspension position
z When closing the discharge grill, the required space is
30mm or more. (Note 3)
Suspension bolt
Height of suspension bracket
1000mm or more
(required space)
z 1500 mm or
more
Required space
z 1500 mm
or more
z When closing the discharge grill, the required space is
790 Suspension position
30mm or more. (Note 3)
Suspension bolt
Height of suspension bracket
1000mm or more
(required space)
unit (mm)
more
z 1500 mm or
more
z 1500 mm or more
Note:
1. Location for manufacture's label: on bell mouth.
2. This is where the signal of infrared remote control
is received. Refer to the drawing of infrared
remote control in detail.
3. When closing the discharge grill (2 or 3 way
discharge), direction of pipe connection will be
limited, please refer to installation manual.
3D013860D
unit (mm)
z 1500 mm or
more
z 1500 mm or more
Note:
1. Location for manufacture's label: on bell mouth.
2. This is where the signal of infrared remote control
is received. Refer to the drawing of infrared
remote control in detail.
3. When closing the discharge grill (2 or 3 way
discharge), direction of pipe connection will be
limited, please refer to installation manual.
3D044898B