Factory Default Settings; Programming Options (Alphabetical List) - C&K systems SYS3316RF Installation Instructions Manual

Table of Contents

Advertisement

HOOK
HOOK
HOOK
HOOK
HOOK
Any address from 8 to 15 can be used. The exact
SWITCHES
SWITCHES
SWITCHES
SWITCHES
SWITCHES
number is not important, as long as each LED
SW1
SW1
SW1
SW1
SW1
keypad in the system has a different address
SW2
SW2
SW2
SW2
SW2
number. Should you accidentally use the same
address for more than one keypad, the system
SW3
SW3
SW3
SW3
SW3
will fail to respond to keypad input. Refer to page
J1
J1
J1
J1
J1
23 (Alpha II keypads with same addresses) for
J2
J2
J2
J2
J2
assistance in correcting this problem.
SW1
SW1
SW1
SW1
SW1
SW2
SW2
SW2
SW2
SW2
Closed
Closed
Closed
Closed
Closed
Open
Closed
Open
Open
Closed
Open
Closed
Open
Open
Open
Open
LED Keypad Backlighting
Hook switch J1 controls the LED keypad's backlighting. When J1 is closed
(default setting), the backlighting will be enabled. Open J1 to disable the
backlighting.
LED Keypad Piezo
Hook switch J2 controls the LED keypad's piezo audible. When J2 is
closed (default setting), the piezo is enabled. Open J2 to disable the piezo.
FACTORY SETTINGS
FACTORY SETTINGS
FACTORY SETTINGS
FACTORY SETTINGS
FACTORY SETTINGS
DEFAULT PROGRAM SETUP
The default programming of the SYS3316RF will allow you to operate it as
a local panel without any additional programming. The actual default
programming values are shown on the Programming Worksheet (last 4
pages of this manual).
Note: If you connect power before wiring the loops, install a
2.2K-ohm EOL resistor across each loop.
Combinations
Installer combination: 0 1 2 3 4 5
User #1 (Master) combination: 1 2 3 4
Users #2 - 32: disabled
Default installer combination: yes
Guest combination: no
Combination required: no
Faulted Arming type: goof-proof
Opening/Closing: no Users authorized to send reports
Duress: disabled
Reporting
Account #1 and #2: disabled
Dialing type: pulse
RPS allowed: yes
Zones
Zone 1 = Entry/Exit delay - SUPERVISED EOL circuit
Zone 2 = doors or windows - SUPERVISED EOL circuit
Zone 3 = doors or windows - SUPERVISED EOL circuit
Zone 4 = doors or windows - SUPERVISED EOL circuit
Zone 5 = doors or windows - SUPERVISED EOL circuit
Zone 6 = doors or windows - SUPERVISED EOL circuit
Zone 7 = doors or windows - EOL circuit
Zone 8 = fire or smoke - supervised EOL circuit
SW3
SW3
SW3
SW3
SW3
KEYPAD ADDRESS
KEYPAD ADDRESS
KEYPAD ADDRESS
KEYPAD ADDRESS
KEYPAD ADDRESS
Closed
8 8 8 8 8
Open
9 9 9 9 9
Closed
10
10
10
10
10
Open
11
11
11
11
11
Closed
12 12
12
12
12
Open
13
13
13 13
13
Closed
14
14
14 14
14
Open
15
15 15
15
15
Zones (cont.)
Zone 9 = interior - SUPERVISED EOL circuit
Zone 10 = interior - SUPERVISED EOL circuit
Zone 11 = interior - SUPERVISED EOL circuit
Zone 12 = interior - SUPERVISED EOL circuit
Zone 13 = interior - SUPERVISED EOL circuit
Zone 14 = interior - SUPERVISED EOL circuit
Zone 15 = interior - SUPERVISED EOL circuit
Zone 16 = interior - SUPERVISED EOL circuit
Emergency soft zone: chirp audible, non-reporting
Fire soft zone: pulsed audible, non-reporting
Police soft zone: steady audible, non-reporting
Testing
Test report interval: 7 days and disabled
Timing
Entry time: 60 seconds and prewarn
Exit time: 30 seconds and prewarn
Bell time: 5 minutes
Unit Control
Local system: yes
Dynamic battery test: off
PROGRAMMING OPTIONS
PROGRAMMING OPTIONS
PROGRAMMING OPTIONS
PROGRAMMING OPTIONS
PROGRAMMING OPTIONS
The following is an alphabetical listing of all SYS3316RF programming
options, including Command Locations and Digit Positions. Digit Posi-
tions are inside parentheses ( ). NOTE: All Command Locations are in
Hexadecimal.
Option
Account #1
Account #2
AC Power Line Frequency
Alarm Receiver Select by Loop
Alarm Reporting Code by Loop
Audible Time
Bell Reverse Operation
Cancel Report Code
Cancel Report Receiver Select
Closing Report Code
Closing Report Receiver Select
Combination Command
Daily Battery Test Enable
Default Installer Combination
Delay Before Dial by Loop
Delay Before Dial Time
Dial Attempts
Dial Type
Disable Loop LEDs
Door Chime Enable by Loop
Duress Report Code
Duress Report Receiver
Emergency Bell Type
Emergency Receiver Select
Emergency Report Code
Entry Delay Time
Entry Pre-alarm Enable
Exit Delay Time
Exit Pre-alarm Enable
Faulted Arming Type
Fire Bell Type
Fire Receiver Select
Fire Report Code
Four Minute Power Up Delay Enable
Group Shunt Enable
Guest Combination
Guest Combination Time
Installer Combination
5
SYS3316RF Installation Manual
Location
0C (1 - 6)
10 (1 - 6)
2F (5)
1F - 26 & 49 - 50 (1)
17 - 1E & 40 - 47 (1 - 2)
2D (5)
2E (3)
2A (5)
2A (6)
2C (3)
2C (4)
09 (2)
2F (2)
09 (3)
30 - 3F (4)
0B (1)
0B (6)
0B (2)
2E (5)
30 - 3F (1)
2D (1)
2D (2)
27 (4)
27 (3)
27 (1 - 2)
2D (3)
2E (1)
2D (4)
2E (2)
09 (4)
28 (4)
28 (3)
28 (1 - 2)
2F (3)
30 - 3F (3)
08 (2 - 6)
09 (1)
00 (1 - 6)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents