C&K systems SYS3316RF Installation Instructions Manual page 15

Table of Contents

Advertisement

CL 2A and 2B
CL 2A and 2B
CL 2A and 2B
CL 2A and 2B
CL 2A and 2B
Command Location 2A: Event Reporting
Command Location 2A: Event Reporting
Command Location 2A: Event Reporting
Command Location 2A: Event Reporting
Command Location 2A: Event Reporting
Digit Position (1): Shunt Receiver Select
Digit Position (1): Shunt Receiver Select
Digit Position (1): Shunt Receiver Select
Digit Position (1): Shunt Receiver Select
Digit Position (1): Shunt Receiver Select
See also CL 17 - 1E & 40 - 47 Digit Positions (5) and (6).
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
Digit Position (2): Restore Receiver Select
Digit Position (2): Restore Receiver Select
Digit Position (2): Restore Receiver Select
Digit Position (2): Restore Receiver Select
Digit Position (2): Restore Receiver Select
See also CL 17 - 1E & 40 - 47 Digit Positions (3) and (4).
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
Digit Position (3): Unit Status Report Code
Digit Position (3): Unit Status Report Code
Digit Position (3): Unit Status Report Code
Digit Position (3): Unit Status Report Code
Digit Position (3): Unit Status Report Code
Valid entries are 0 - F.
The panel will add a fixed extension digit when reporting. Fixed codes are listed below.
Program a 0 at this position to disable Unit Status Reporting.
Digit Position (4): Unit Status Receiver Select
Digit Position (4): Unit Status Receiver Select
Digit Position (4): Unit Status Receiver Select
Digit Position (4): Unit Status Receiver Select
Digit Position (4): Unit Status Receiver Select
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
Digit Position (5): Cancel Report Code
Digit Position (5): Cancel Report Code
Digit Position (5): Cancel Report Code
Digit Position (5): Cancel Report Code
Digit Position (5): Cancel Report Code
Valid entries are 0 - F.
The panel will add the User ID # as the second digit when reporting.
Program a 0 at this position to disable Cancel Reports.
Digit Position (6): Cancel Report Receiver Select
Digit Position (6): Cancel Report Receiver Select
Digit Position (6): Cancel Report Receiver Select
Digit Position (6): Cancel Report Receiver Select
Digit Position (6): Cancel Report Receiver Select
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
UNIT STATUS FIXED EXTENSION CODES
UNIT STATUS FIXED EXTENSION CODES
UNIT STATUS FIXED EXTENSION CODES
UNIT STATUS FIXED EXTENSION CODES
UNIT STATUS FIXED EXTENSION CODES
1 = Low battery
2 = AC fail
3 = Bell fuse fail
5 = Failed to communicate
6 = Battery restore
Command Location 2B: Test Report
Command Location 2B: Test Report
Command Location 2B: Test Report
Command Location 2B: Test Report
Command Location 2B: Test Report
Digit Positions (1) and (2): Test Report Code
Digit Positions (1) and (2): Test Report Code
Digit Positions (1) and (2): Test Report Code
Digit Positions (1) and (2): Test Report Code
Digit Positions (1) and (2): Test Report Code
Valid entries are 0 - F.
Program 00 to disable Test Reports.
Digit Positions (3): Test Report Receiver Select
Digit Positions (3): Test Report Receiver Select
Digit Positions (3): Test Report Receiver Select
Digit Positions (3): Test Report Receiver Select
Digit Positions (3): Test Report Receiver Select
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
Digit Positions (4): Test Report Interval
Digit Positions (4): Test Report Interval
Digit Positions (4): Test Report Interval
Digit Positions (4): Test Report Interval
Digit Positions (4): Test Report Interval
1 = 1 hour
5 = 24 hours
2 = 2 hours
6 = 7 days
3 = 4 hours
7 = 14 days
4 = 12 hours
8 = 21 days
9 = 30 days
Default Values
Default Values
Default Values
Default Values
Default Values
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
7 = AC restore
8 = Bell fuse restore
B = Watchdog reset
C = Completed programming
Default Values
Default Values
Default Values
Default Values
Default Values
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
0 = 1 hour if armed
1 = 2 hours if armed
2 = 4 hours if armed
3 = 12 hours if armed
4 = 24 hours if armed
1
1
2 2 2 2 2
A A A A A
(1)
(2)
2 2 2 2 2
B B B B B
NOTE: CL A0 must be programmed to
correctly set time of test.
15
15
15
15
15
SYS3316RF Installation Manual
A
1
D
1
(3)
(4)
(5)
(6)
0
0
1
6
(1)
(2)
(3)
(4)
#
#

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents