There now follows the specifications of the panel. These include power
consumption, panel dimensions etc.
PROCESSOR
VERSION
SPECIFICATION FOR SOFTWARE REVISION NUMBER
The software revision number is located on the top of the main processor
POWER
SPECIFICATION
SUPPLY

KEYPADS

GENERAL

FACTORY
DEFAULTS

SPECIFICATIONS

Power Supply

Mains Supply Voltage
PSU output voltage
Maximum output current
Aux. current
Battery Fuse
Panel Quiescent
Keypads
Supply Voltage
Quiescent Current
Active
Maximum number allowed
General
Normal operating temperature
Humidity
Dimensions
Control Panel Weight
Stand by Battery
Maximum Cable Run
Use

Factory Defaults

User/customer Code 1
User/customer Code 2
Engineer Code
Circuit 1
Circuit 2
Circuit 3
Circuit 4
Circuit 5
Circuit 6
Circuit 7
Circuit 8
Full Set Exit Time
Night set Exit Time
Entry time
Sounder Ring Time
Chimes
230 V AC Nominal
13.6 V Nominal
1 A (total)
500 mA Max.
1 A (20 mm)
40 mA
12 V
20 mA
45 mA
6
0°C to 40°C
10 to 90% R.H. non condensing
263 mm (W) 223 mm (H) 82 mm (D)
2.7 kg Excluding Battery
1.2 Ah 12 V Rechargeable Lead Acid
2.1 Ah max.
100 Metres per run.
For internal use only
1234
Disabled (0000)
7890
Entry Circuit. (Fixed)
Alarm Circuit isolated in Night set.
Alarm Circuit.
Alarm Circuit.
Alarm Circuit.
Alarm Circuit.
Alarm Circuit.
P.A (Personal Attack)
30 Seconds
15 Seconds
30 Seconds
15 Minutes
Disabled
3
V1.0