Air volume/direction
Air volume
Direction
Low
Return
Return
Setting
Setting
Air volume/direction
Air volume
Direction
Low
Return
Setting
Return
Setting
Airflow direction
setting (up/down)
Air volume/direction
Air volume
Direction
Low
Return
Return
Setting
Setting
Airflow direction
setting (left/right)
Movement of airflow direction flap (blade)
Under the operation conditions shown below, airflow direction is controlled automatically. Actual
operation may thus be different from what is displayed on the remote controller.
Operation
condition
13
4PWEN71265-1A_01_OM_ENGLISH.indb 13
<Airflow Direction Setting>
• With Direction selected, set the desired airflow
Position 0
direction from,
Position 2
,
Auto
and
using the "
Note
Swing
• Airflow direction appears on the screen as below.
0
1
2
3 4
Up/down direction
• When you set one of positions 0 to 4, the airflow
direction flap stay in a fixed position.
Swing
• Selecting
Swing
flap to swing position 0 to 4.
For the swing setting only, all positions will be displayed.
• Setting
Auto
temperature and the presence or absence of the
person.
However, in Fan mode, the airflow direction flap
will be to position 0.
(This function may not be available depending on
the type of indoor unit.)
• Press Menu/Enter button to confirm the settings
and return to the Basic screen.
• Room temperature is higher than the set temperature (in Heat/Auto mode).
(Discharge horizontally so that it does not discharge directly toward your body.)
• When the air conditioner goes into Heating Operation or Defrost
Operation (in Heat/Auto mode).
(Discharges horizontally to avoid a cold draft for the room occupants.)
• Under continuous operation with the airflow discharges horizontally (in Cool/Auto mode).
(Discharges in the automatic set direction for a period of time to prevent
condensation on the horizontal flap.)
• Under continuous operation with the airflow discharges downward (in Cool/Auto mode).
(Discharges in the automatic set direction for a period of time to prevent
condensation on the horizontal flap.)
Position 0
Position 1
,
Position 3
,
Position 4
,
" buttons.
0
1
2
Left/right direction
will cause the airflow direction
will varied airflow direction by room
,
Swing
,
0 : Position 0
1 : Position 1
4
2 : Position 2
3
3 : Position 3
4 : Position 4
1/29/2013 6:40:16 PM