3.4
Water connections
Novella boilers are designed and made for
use in central heating systems, but can also
be used to generate domestic hot water if
connected to a suitable storage cylinder.
The specifications of the water fittings are as
follows:
MI
CH outlet
RI
CH return
b
The "RO120 storage cylinder water
connections kit" (part number 596369)
adapts the boiler's water connections to
a different diameter:
MI
CH flow
RI
CH return
b
The choice of system components and
the method of their installation are left
up to the heating engineer installing the
system. Installers must use their experti-
se to ensure proper installation and fun-
ctioning in conformity to all applicable
legislation.
14
b
Circuits filled with anti-freeze must be fit-
ted with water disconnectorsrici.
3.5
Electrical connections
Il collegamento alla rete elettrica deve essere
realizzato tramite un dispositivo di separazio-
ne con apertura onnipolare di almeno 3 mm.
L'apparecchio funziona con corrente alternata
a 230 V~50 Hz, ha una potenza elettrica di
150 W ed è conforme alla norma EN 60335-1.
b
The following instructions are mandatory:
- Install a multi-pole magnetic thermal
trip switch and disconnector confor-
ming to IEC-EN standards (with a con-
tact gap of at least 3 mm).
- Respect the polarity of the L1 (Phase)
- N (Neutral) connections.
- Use cables with insulation and cross
section conforming to applicable stan-
dards (minimum cross section 1.5
mm2).
Ø 1"1/4 F
Ø 1"1/4 F
Ø 3/4" F
Ø 3/4" M
MI
- Always refer to the electrical wiring dia-
grams in this manual when performing
any electrical work.
- Ensure that an efficient ground con-
nection is provided.
a
It is strictly forbidden to use fuel and/
or water pipes to ground the appliance.
The manufacturer declines all respon-
sibility for damage caused by failing to
ground the appliance adequately.
RI
Fig. 3.1