Service Mode; Check Signal Strength - A30; Check Link Reliability - A31; Reboot The Rf30-Em - A32 - Siemens RF30-EM Configuration Manual

Codoor
Table of Contents

Advertisement

Available languages

Available languages

System mode
9.2

Service mode

9.2.1

Check signal strength - A30

9.2.2
Check link reliability – A31
9.2.3
Reboot the RF30-EM – A32
9.2.4
Reconnect the network – A34
16
Siemens AG
1.
To enter the service mode quickly press key B followed by a long press on
key B and wait until the buzzer confirm.
2.
Enter the 6-digit Administrator code
The commands A30, A31, A32 or A34 can then be performed.
3.
To leave this mode press B .
The A30 command displays the signal strength. It will proceed for 5 minutes or until
a key press or card use. Note that although the green LED lit the command A31
should be performed to confirm a reliable data transmission.
LED
The command A31 displays the reliability of the data transmission. It will proceed
for 5 minutes or until a key press or card use.
Buzzer
Continuous tones.
Non continuous
tones.
Error tone.
The command A32 performs a reboot of the firmware in the RF30-EM.
The command A34 should be performed if e g a router has been added to the sys-
tem. The system tries to reconnect the RF30-EM to the Segment Controller.
Description
Signal strength excellent.
Signal strength sufficient.
Signal strength OK.
Recommendation
Relocate the router.
Signal strength bad.
Relocate the router.
Description
Link reliability OK. Sending and receiving messages.
One or more messages lost.
Recommendation
Relocate the router.
Link unreliability. Messaging took more then 0.7 s.
Relocate the router.
04.2010