Troubleshooting - Siemens RF30-EM Configuration Manual

Codoor
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting

15
Troubleshooting
32
Siemens AG
Symptom
Lock does not open when card/Group code/PIN is
entered.
RF30-EM is in unlocked position
RF30-EM does not sound following key presses.
Batteries are rapidly discharged.
The RF30-EM does not seems to operate
Red LED flash once and buzzer sounds when
card is used.
An error sound is heard when a card is used
Remedy
Check that the correct card/Group code/PIN
has been entered.
The cards may be injured.
Make sure the handle is not pressed down as
the code is entered
Check that the handle is not sagging.
Check that RF30-EM is fitted exactly vertical.
Check that the lock is not fitted too tightly to the
door, in which case the handle could be
jammed.
Check that the red mark on the follower for the
lever handle spindle is pointing downwards.
Set RF30-EM to locked position (if required).
See section 11.4 Lock/unlock door.
Activate the buzzer. See section
11.5 Disable/enable buzzer.
Check the batteries and change any discharged
batteries. See section 10.3 Change batteries.
Frequent use requires frequent change of
batteries. See section 10.3 Change batteries.
Check whether the handles returning to the
horizontal position.
Adjust the PIR sensor. See section 10.4 Adjust
the PIR sensor.
Check if the RF30-EM is in offline mode. See
section 7.7 LED status when connecting.
If e g a new router is connected the command
A34 may be performed to reconnect the RF30-
EM to the network. See section 9.2.4
Reconnect the network – A34
Check if the card is unvalid for offline
Could be a mechanical problem (e.g. a wrong
handle).