Ethernet Led; Serial Interface Rs232 - Russound MCA-C3 User And Installation Manual

6 source multizone controller amplifier
Hide thumbs Also See for MCA-C3:
Table of Contents

Advertisement

1. Confirm the Ethernet Port LED's illuminate after the MCA-C3 power is on.
The Green LED closest to the Serial Port will blink several times after the
MCA-C3 boots up. The yellow LED is checked during the WOL section.
2. Continue by performing the
1. Contract Manufacturer continue to "RS485 Test of Link Ports"
Russound Personnel perform the Serial Interface Test.
2. Unplug the serial cable attached to the RCK DB9 plug and connect the cable
to the MCA-C3 Serial Interface RS232 port. If you have a DB9 Switch
connected set the switch to the MCA-C3 serial Interface RS232 port.
3. Open the RNET Version Reader v1.01.02 obtained from Russound.
4. Set each button on RNET Version Reader GUI to match the left picture.
Actual Firmware and Bootloader Version will be different than picture
5. Left click the "Get Product Info" button.
6. "Product Name" displays "MCA-C3".
"Firmware Version" displays the firmware version loaded.
"Bootloader Versoin" displays the bootloader version.
Note: Actual version may be different than the picture above
7. Confirm with Russound SQA that the current versions are installed.
8. Close RNET Version Reader v1.01.02.
9. Unplug the serial cable attached to the MCA-C3 Serial Interface RS232 port.
Connect the cable to the RCK DB9 plug. If you have a DB9 Switch
connected set the switch to the RCK DB9 serial Interface RS232 port.
10. Return to
"Program
needs to be installed then continue with

Ethernet LED

"Serial Interface RS232"

Serial Interface RS232
BootLoader" if the latest firmware
MCA-C3 Test Procedure
Page 37 of 77
section.
"RS485 Test of Link Ports"
script.