Triggers - Russound MCA-C3 User And Installation Manual

6 source multizone controller amplifier
Hide thumbs Also See for MCA-C3:
Table of Contents

Advertisement

Note: A reading of 10.5 to 11.6 for 12VDC Trigger Outputs
is acceptable. 11.4 VDC is normal.
1. Obtain the adconlcd.hex file from Russound Engineering.
Load this firmware file to the PIC18F452 on the IR Switcher PCB.
The PIC 18F452 needs to have firmware loaded to perform the tests.
To load firmware on the PIC on the IR Switcher PCB:
1) Remove jumper J46 located above Source 12 U24.
2) Move J30 jumper to the right two pins of the header.
3) Pin 1 of J31 programming header is the MCLR pin.
Place all jumpers back in the following positions once firmware is loaded.
1) Install jumper J46 on the left two pins of the header.
2) Move J30 jumper to the left two pins of the header.
Note: The IR Switcher PCB has 8 analog to digital converters.
Only 8 Triggers can be monitored at one time.
2. Press the space bar at the "Triggers" script.
3. All Trigger LED's, Triggers 1 -6 and HT will be turned off.
4. You will observe all LED's on the right column go dark.
5. Trigger Output number 1 will turn on for 1.5 seconds.
6. "Trigger 1: 11.4" will register on the IR Switcher PCB display.
7. Trigger Output number 1 will turn off for 1.5 seconds.
8. "Trigger 1: 00.0" will register on the IR Switcher PCB display.
9. Trigger Output number 2 will turn on for 1.5 seconds.
10. Then "Trigger 2: 11.4" will register on the IR Switcher PCB display.
11. Trigger Output number 2 will turn off for 1.5 seconds.
12. Each time a Trigger turns off the IR Switcher PCB will display:
"Trigger 1: 00.0
13. This sequence will occur for each Trigger Output.
14. Should any Trigger fail to turn off this sequence will be broken.
15. The Trigger test passes only when:
1) Each Trigger Output displays it's Trigger on number and correct voltage.
2) Each Trigger Output displays "Trigger 1: 00.0" and continues to the next
Trigger Output number.
3) All Trigger LED's on the right column of the IR Switcher PCB are dark.

Triggers

MCA-C3 Test Procedure
Page 60 of 77

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents