Diagnostics
Service Tests
When the Test Mode has been entered, the first test will be for the defrost test.
101 Defrost heater and Defrost Circuit
Press the refrigerator temperature "+" (up) or "–" (down) keypad to energize or de-energize the defrost
circuit. The display will read OFF when de-energized as shown below. op when energized with open defrost
thermostat and Cl when energized with closed defrost thermostat.
1 0 1
Press either button to toggle
through test cycles
102 Compressor/Condenser Fan
Press the refrigerator temperature "+" (up) or "–" (down) keypad to toggle Compressor/Condenser fan ON
and OFF.
1 0 2
Press either button to toggle
through test cycles
112 Freezer Fan
Press the refrigerator temperature "+" (up) or "–" (down) keypad to toggle Freezer Fan OFF, High or Low speed.
1 1 2
Press either button to toggle
through test cycles
note: Display will show 11.0-14.0 volts for HIGH and 7.75-8.25 volts for LOW. When off 0.0 will be displayed.
© 2012 Viking Preferred Service
O F F
Press either button to
cycle defrost On and Off
O F F
Press either button to cycle
compressor and condensor
fan motor ON and OFF
O F F
Press either button to cycle
freezer fan OFF, High or
Low speed