How To Set Time And Date; How To Start Walk Test Mode - ADC Ultra-8/16 Operator's Manual

Table of Contents

Advertisement

At any time you can enter in the address for the telephone number just to view the
currently programmed value then press the <PROGRAM> button to move on to another
address.
Note: Address 6911 = PH # 1, 692 = PH# 2 to 696 = PH# 6.
(Note: on the LED keypad "0" is indicated by LED "A" and "9" by LED "B")

How to set Time and Date

The alarm system has an internal clock that may be used to automatically Arm or Disarm
the alarm or turn Outputs On or off. It is also used to identify when events occurred in
memory via the LCD keypad. Should you need to change the Time & Date it must be
done from CLIENT mode.
To change the Time & Date press
1 - Press <PROGRAM> <403> <ENTER> <1-7> <ENTER>
Where 1-7 = the current day (1=Sun, 2 = Mon to 7 = Sat)
2 - Press <PROGRAM> <401> <ENTER> <HHMM> <ENTER>
Where HH = Hour in 24 Hour Format and MM = Minutes
3 - Press <PROGRAM> <405> <ENTER> <1-31> <ENTER>
Where 1-31 = the current date
4 - Press <PROGRAM> <406> <ENTER> <1-12> <ENTER>
Where 1-12 = the current month
5 - Press <PROGRAM> <407> <ENTER> <YY> <ENTER>
Where YY = current year, e.g. 02=2002

How to start Walk test Mode

While in CLIENT mode a User with the proper authority can start walk-test mode. This
special mode latches the alarm signals from detectors at the keypad initiating the test so
that one person can trigger every detector connected to the alarm then return to the
keypad to verify operation. On terminating Walk-test mode the test results are put into
the memory buffer so they can be viewed at a later time.
To start Walk-test mode while in CLIENT mode press <PROGRAM> <956> <ENTER>
The keypad buzzer will beep at 1-second intervals
Next trigger every detector connected to the panel then return to the keypad and all of
the zones that were triggered will be displayed at the keypad.
To terminate Walk-test mode press <ENTER>
The keypad will stop beeping and automatically exit CLIENT mode.