Contents Introduction ................. 5 Meet the Ultra Alarm Control System ..........5 Typical Alarm System Configuration...........5 Keypad Description ............... 6 Buttons..................6 Audible Signals ................7 Indicators ..................7 KEYPAD TAMPER (wrong code alarm)........7 Display..................8 Summary of Functions..............8 Operation ..................11 How to Arm the System before Exit ........... 11 How to Arm the System when Staying Home ......
Page 4
How to Add or Change User Code............19 How to Add or Change Telephone Numbers........19 How to set Time and Date ..............20 How to start Walk test Mode .............. 20 Customizing your Keypad ..............21 How to Adjust Keypad Backlight Level..........22 How to Adjust Buzzer Tone..............
Introduction Meet the Ultra Alarm Control System Thank you for choosing to protect your premises with a Ultra-8/16 of Australian Security Supplies & ADC. Ultra Alarm panel of Australian Security Supplies is a highly advanced, multifunction Wireless alarm control system, designed to flawlessly manage your security system at home or at business, protects you against burglary and supports the operation of electronic devices.
Keypad Description The LCD Keypad shows all the information required to operate the system. The User communicates with the alarm system via the keypad. The Keypad displays continuous information about the status of the alarm system, and enables the User to operate the system in different modes, change settings and program Users' access codes.
KEYPAD TAMPER (wrong code alarm) A wrong code or Keypad Tamper alarm is generated by the Ultra-8/16 after 4 consecutive invalid code entries. The controller will not “Lock-Out” the keypad at this point but simply create an alarm condition that may be reported to a monitoring company via the dialler.
Display The LCD window holds 2 rows of 16 characters each. The display shows: • System Messages • Open Zones • System Status • Trouble Messages • Memory Events • Description of zones • Zone numbers during programming • Device numbers during control Summary of Functions Function Keys...
Page 9
Function Keys Description Notes Disarm Disarms the C O D E ENTER Stay system Disarm Disarms the STAY Stay system Bypass Bypasses a Repeats the Zone # BYPASS zone(s) procedure to un- ENTER bypass zones Initiate CONTROL Activates Press simultaneously CHIME Panic emergency...
Page 10
Increase Hold <CONTROL> and STAY CONTROL press <STAY> backlight repeatedly to increase level light Decrease Hold <CONTROL> and BYPASS CONTROL press <BYPASSS > backlight repeatedly to decrease level light Increase Hold <CONTROL> and CONTROL press <MEM> backlight repeatedly to increase level light Decrease...
Operation How to Arm the System before Exit Preparing the System for Arming Verify that the green <Ready> indicator is lit. This indicator is lit only when all zones are closed (all doors, exits and windows are closed and motion in the protected area is restricted or bypassed).
During this delay time, a slow beeping is heard to indicate that the system is not armed yet and reminds you to leave the protected area. If you must disarm the system during the exit delay, press <ARM>. Disarming the System Enter User’s code and press <ENTER>.
Areas Disarmed A - - - How to Arm Partitions The protected area can be grouped into 4 separate partitions (A, B, C, D). The system can be grouped for User ‘s convenience to separate, in a business environment, the offices from the warehouse area, or in a private residence, the different rooms of the home, e.g., living room, bedroom, etc.
To disarm partition, see "Disarming the System". Note: to arming partition with code see page 9 “How to arm the system before exit” How to Bypass Zones Bypass any zone that cannot be closed. You can bypass selected zones prior to arming. It is also used to temporarily exclude a faulty zone from service, which requires repair.
Emergency Alerts This three special key’s function is best programmed by your installer to suit your individual situation. Most commonly it is used in a panic situation. These are a “PANIC”, “FIRE”, and “MEDICAL” alarm. Pressing two buttons simultaneously generates the Fire and Medical alarms How to initiate Panic Press the <PANIC>...
Table 4: System Messages Message Description/Action Battery Low The backup battery is low (charger or battery failure) Main Failure The main power is disconnected, or caused by power outage. Telephone Line Failure The line is disconnected Radio Device Battery Low Replace battery of the particular device Supervise Detector Radio detector failed to communicate...
How to Display Events from Memory The system memory stores the last events. Press <MEMORY> to display list of events Following the display of current system alarms the panel will then sequence through the 255 historical memory events starting at the most recent event. The system will display the last event and automatically scroll to the next one every 2.5 seconds, and a beep is emitted.
Press <PROGRAM> enter Master code and <ENTER>. The Program indicator lights up to indicate that the system is in User programming mode. If you get a single long beep at this point and the Program LED doesn’t turn on, it means your code cannot access Program mode.
new code will be flashed to you and 3 short beeps to indicate correct entry or 1 l o ng beep if not accepted. Press <PROG> and <ENTER> exit user Code Program mode. Press <PROG> enter Master code and <ENTER>. The display will show “Client Mode”. Client Mode How to Add or Change User Code While in CLIENT mode, press <PROG>...
At any time you can enter in the address for the telephone number just to view the currently programmed value then press the <PROGRAM> button to move on to another address. Note: Address 6911 = PH # 1, 692 = PH# 2 to 696 = PH# 6. (Note: on the LED keypad “0”...
How to Answer an in-coming call From time to time your installer may need to access the alarm from a remote PC to make changes to your programming and for security reasons they may have configured the alarm so that an authorized person on-site is required to make the alarm system answer the in-coming call.
Table 6: Summery of Alphanumeric Keys Button # Press Press Press Press * (‘) # (<) = (>) A (a) B (b) C (c) D (d) E (E) F (F) G (g) H (h) I (i) J (j) K (k) L (l) M (m) N (n)
To decrease LCD backlight, hold <CONTROL> and press <BYPASS> repeatedly until the light goes off. To increase keyboard backlight, hold <CONTROL> and press <MEM> repeatedly until the light is increased to its maximum. To decrease keyboard backlight, hold <CONTROL> and press < > repeatedly until the light goes off.
Page 24
Assuming the status message we received was "Area A alarm is Armed" If we press the "*" key, Area "A" will be Disarmed and we would receive a status message "Area A alarm is Disarmed" (or whatever message is programmed by the installer) While you are on-line with the panel you can move between menu options by entering the code of the option you want to control.
Warranty CROW LIMITED WARRANTY (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose numbers are printed on the printed circuit board inside his product.
Page 26
Use the following form to record your changes and customizations. User Zone Name Device Zone Name Designation...