Parts Replacements - AMBROGIO basic User Manual

Robot
Hide thumbs Also See for basic:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 64
Problem
The led (D) of the
power supply unit
does not turn on.
B
A
C
The led (C) (green)
of the transmitter
is on.
The led (C) (oran-
D
ge) of the transmit-
ter turns on
repeatedly with
consecutive
flashes (less than
4).
The led (C) (red) of
the transmitter is
on.
PARTS REPLACEMENT REMINDERS
Important
Always replace and repair the parts in
compliance with the Manufacturer's
instructions, otherwise contact the As-
Causes
There is no power volta-
ge
Blown fuse
Interrupted perimeter
wire
Perimeter wire too long.
Perimeter wire damaged
or oxidized.
Connections not perfor-
med correctly.

PARTS REPLACEMENTS

sistance Service if these operations
are not described in the manual.
- 55 -
Solutions
Check that the position of the
cursor (B) matches with the
power voltage and that the
push button (A) is on "ON".
Check that the power supply
unit is correctly connected to
the power socket.
Get the fuse replaced by the
nearest authorized Assistan-
ce centre.
Stop the robot in safety condi-
tions (see "Robot safety
stop").
Press the button (A) of the
power supply unit on OFF.
Carry out the joint of the peri-
meter wire.
Install the signal amplification
kit.
Check any joints. if necessary,
replace the wire.
Get the check carried out by
the nearest authorized Assi-
stance centre.
User's manual
GB

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

DeluxeEvolution

Table of Contents