FIELD
FUNCTION
––––––––
–––––––––––––––
SYSTEM SETUP (*20-*27)
*20
INSTALLER CODE
*21
QUICK ARM ENABLE
*22
RF SYSTEM TYPE
*23
FORCED BYPASS FUNCTION
*24
RF HOUSE ID CODE [0][0]
WIRED EXPANSION/RELAY USED †
*25
*26
VOICE MODULE ACCESS CODE
OUTPUT TO LONG RANGE RADIO †
*27
ZONE SOUNDS AND TIMING (*28-*39)
SINGLE ALARM SOUNDING/ZONE †
*28
*29
FIRE SOUNDER TIMEOUT
*30
ALARM BELL TIMEOUT
*38
ENTRY DELAY
*39
AUDIBLE EXIT WARNING
DIALER PROGRAMMING (*40-*50)
*40
PABX ACCESS CODE
If fewer than 4 digits entered, exit by pressing
*41
PRIMARY PHONE No.
If fewer than 12 digits entered, exit by pressing
*42
SECONDARY PHONE No.
If fewer than 12 digits entered, exit by pressing
*43
SUBSCRIBER ACCT No.
*45
PHONE SYSTEM SELECT
*46
REPORT FORMAT
*47
SPLIT/DUAL REPORTING
**
A 10-digit code is sent to the pager consisting of
a 4-digit Subscriber #, a 3-digit Event code, & a
3-digit User or Zone #. See Installation
Instructions for an explanation of the 10-
digit code.
† Entry of a number other than one specified will give unpredictable results.
ADEMCO VIA-30P
PROGRAMMED VALUES
–––––––––––––––––––––––––––––––––
In fields *40, *41, *42, enter up to the number of digits shown. Do not fill unused spaces.
Enter 0-9; #+11 for ' '; #+12 for '#'; #+13 for a pause.
#+14 for E; [#+15 for F]. Enter
If only 3 digits used, exit by pressing
Examples: For Acct No. 1234 , enter:
[0 = 3+1, 4+1 ADEMCO L/S STANDARD]
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD

PROGRAMMING FORM

SE
Enter 4 digits, 0-9...[4] [1] [1] [1]
[0 = no]; 1 = yes
[0 = none]; 1 = 5700 (4281); 2 = 5800 (5881)
[0 = none]; 1 = bypass open zones
MUST enter (01-31) for 5700 System. Enter also for 5827 Keypad
[0 = none]; 1 = 4219; 2 = 4229; 3 = 4204
1st digit: Enter 1–9; 2nd digit: Enter only #+11 for ' ', #+12 for '#'.
[0] in either position = disabled.
[0 = no]; 1 = yes. If yes selected, dialer reports to PRIMARY No. (field
*47) will also be sent via LRR. All dialer and LRR reports will be in Contact
ID format (overriding field *46 selection).
[0 = no]; 1 = yes
[0 = fire sounder timeout]; 1 = no fire sounder timeout
0 = none; [1= 4 min]; 2 = 8 min; 3 = 12 min.; 4 = 16 min.
0 = 0 sec ; 1= 20 sec; [2 = 30 sec]; 3 = 45 sec; 4 = 60 sec; 5 = 90 sec
EXIT Delay = ENTRY Delay + 15 sec
0 = no; [1 = yes]
Enter up to 4 digits.
(and press 41, if entering next field). To clear entries from field, press
(and press 42, if entering next field). To clear entries from field, press
(and press 43, if entering next field). To clear entries from field, press
as 4th digit, if 3+1 dialer reporting is to be used.
(and press next field). To clear entries from field, press
For Acct No. B234, enter:
For Acct No. 123, enter:
If Cent. Sta. IS NOT on a WATS line: [0 = Pulse Dial]; 1 = Tone Dial
If Cent. Sta. IS on a WATS line:
Also see field *27.
[0 = Disable (Backup report only)]
TO PRIMARY PHONE No.
1 =Alarms, Restore, Cancel
2 =All Reports except Open/Close, Test
3 =Alarms, Restore, Cancel
4 =All Reports except Open/Close, Test
5 =
All Reports
( Dual Reporting)
TO PRIMARY PHONE No.
6 = All reports except Open/Close
7 = All reports
8 = All reports
9 = All reports except Open/Close
*
Can only be used if Primary reporting is Ademco Contact ID.
–3–
[
] = Default Value
or 5827BD Keypad.
Enter up to 12 digits.
Enter up to 12 digits.
Enter 0-9; #+11 for B; #+12 for C; #+13 for D;
1
2
3
#+11
2
3
1
2
3
2 = Pulse Dial ; 3 = Tone Dial
6 or undefined = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
TO SECONDARY PHONE No.
Other Reports
Open/Close, Test
All Reports
All Reports
All Reports
TO PAGING No.
**
Alarms, Open/Close, Troubles
**
Alarms, Troubles
**
Alarms, Open/Close, Troubles
**
Alarms, Open/Close for Users 5 –
25, Troubles
40 .
41 .
42 .
43 .
4
4
*
(SECONDARY)