I N TH E P R E V I O U S P A G E ' S Z O N E A S S I G N M E N T T A B L E :
Zn = ZONE NUMBER
ZT = ZONE TYPE
RC = ALARM REPORT CODE
In = LOOP INPUT DEVICE
L = LEARNED RF INPUT Used with self-learning (5800) RF Loop Input Devices. Record transmitter input number.
TO PROGRAM SYSTEM STATUS, & RESTORE REPORT
CODES (*60-*75):
With a 3+1 or 4+1 Standard Format: Enter a code in the first box:
1-9, 0, B, C, D, E, or F. Enter "#+10" for 0, "#+11" for B, "#+12" for
C, "#+13" for D, "#+14" for E, "#+15" for F.
A "0" ( not "#+10") in the first box will disable a report.
A "0" ( not "#+10") in the second box will result in automatic
advance to the next field when programming.
With an Expanded or 4+2 Format: Enter codes in both boxes (1st
and 2nd digits) for 1-9, 0, or B-F, as described above.
A "0" ( not "#+10") in the second box will eliminate the expanded
message for that report.
A "0" ( not "#+10") in both boxes will disable the report.
With Ademco Contact ID Reporting: Enter any digit (other than
"0") in the first box, to enable zone to report (entries in the second
boxes will be ignored).
A "0" ( not "#+10") in the first box will disable the report.
Examples: For Code 3 (Single Digit), enter:
For Code 32 (Two Digits), enter:
For Code B2 (Hexadecimal) enter:
SYSTEM STATUS REPORT CODES (*60-*68)
*60
TROUBLE REPORT CODE
*61
BYPASS REPORT CODE
*62
AC LOSS REPORT CODE
*63
LOW BATTERY REPORT CODE
*64
TEST REPORT CODE
*65
OPEN/EXIT ALARM REPORT CODE
2nd digit of OPEN REPORT is automatically sent as the
user number if expanded or 4+2 reporting is selected.
2nd digit of EXIT ALARM REPORT is automatically sent as
the 2nd digit of the zone alarm report code programmed in
*56, if expanded or 4+2 reporting is selected.
*66
AWAY/STAY CLOSE REPORT CODE
2nd digit of any CLOSE REPORT is automatically sent as
the user number, if expanded or 4+2 reporting is selected.
*67
RF XMTR LOW BAT REPORT CODE
*68
CANCEL REPORT CODE
RESTORE REPORT CODES (*70-*75)
*70
ALARM RESTORE REPORT CODE
2nd digit is automatically sent as the 2nd digit of the
zone alarm report code programmed in *56, if
expanded or 4+2 re porting is selected.
Zone Nos. are from 05 to 63, 95, 96. Some are pre-assigned.
With Field *25 set for auxiliary wired loops (4219 or 4229), use Zone Nos. 10–17 for loops A-H.
With Field *22 set for RF (5700 or 5800), use Zone Nos. 18-63 if 4219/4229 is ALSO used,
or 10-63 if 4219/4229 is NOT used.
00 = Zone Not Used
05 = Trouble Day/Alarm
01 = Entry/Exit
Night
02 = Do not use
06 = 24 Hr Silent
03 = Perimeter
07 = 24 Hr Audible
04 = Interior Follower
08 = 24 Hr Aux
09 = Fire
Two Hex Digits. For each Hex Digit, enter: 00–09 for 0–9,
If "00" is entered in the first pair of boxes, there will be no report for that zone.
For contact ID reporting, this is an enabling code only. Make any hex digit entry (other than "00") in the first
pair of boxes. The second pair of boxes will be ignored.
HW: Hard Wire
AW: Aux Wire (4219 or 4229)
3
3
#+11
/
/
10 = Interior w/Delay
20 = Arm–Stay*
21 = Arm–Away*
22 = Disarm*
23 = No Alarm Response
* 20, 21, and 22 used for 5800 RF systems only.
10 for A, 11 for B, 12 for C, 13 for D, 14 for E, 15 for F.
Enter 3 for RF: Supervised RF
Enter 4 for UR: Unsupervised RF
Enter 5 for BR: Button Type RF
*71
TROUBLE RESTORE REPORT CODE
*72
BYPASS RESTORE REPORT CODE
*73
AC RESTORE REPORT CODE
*74
LOW BAT RESTORE REPORT CODE
*75
RF XMTR LO BAT RST REPORT CODE
OUTPUT AND SYSTEM SETUP (*80-*92)
*80
OUTPUT RELAYS
*81
ZONE LISTS FOR
OUTPUT RELAYS
*82
CUSTOM ALPHA EDITING: (Also entered from field *56):
See procedure in instructions.
*83
SEQUENTIAL MODE: Used for enrolling transmitters after
all other zone information has been programmed.
0
( See procedure in iInstallation Instructions)
2
* 91
OPTION SELECTION
2
"0" for UL installations
*92
REPORTS PER ARMED PERIOD
[0 = 10 max total alrm + alrm restore], 1 = unlimited
DOWNLOAD INFO (*94, *95)
*94
DOWNLOAD PHONE No.
Enter up to 12 digits: 0-9; #+11 for ' '; #+12 for '#'; #+13
for a pause. Do not fill unused spaces. If fewer than 12
digits entered, exit field by pressing
entering next field).
To clear entries from field, press
*95
RING DET COUNT FOR DOWNLOADING
[0=Disable Station Initiated Download]; 1-14=number of
rings (1-9, #+10=10, #+11=11, #+12=12, #+13=13,
#+14=14); 15=answering machine defeat (#+15=15)
*96
INITIALIZES DOWNLOAD ID , SUBSCRIBER ACCOUNT
No. FOR INITIAL DOWNLOAD: No entry required.
*97
SETS ALL PROGRAM FIELDS TO DEFAULT VALUES:
No entry required.
TO EXIT PROGRAM MODE (*98 or *99)
Press
98 or
continuing.
*98
EXITS PROGRAMMING MODE and prevents re-entry by:
Installer Code + Code + 0.
*99
EXITS PROGRAMMING MODE and
allows re-entry by: Installer Code + Code + 0
or by: Power-up +
–5–
DEFAULT VALUES
Zn: 05
06
ZT: [09] [07] [06] [00] [00]
These are automatically
assigned, except "UR"
and "BR" for 5800 RF.
Program only if Relays are to
be used. See next page.
[0 = None]; 4 = AAV
94 .
99 if exiting programming, or next field number if
+ #.
07
95
96
(and press 95, if