TO PROGRAM
SYSTEM STATUS
AND RESTORE
REPORT CODES
( 60 – 68, 70 – 75)
SYSTEM STATUS
REPORT CODES
( 60 – 68)
With a 3+1 or 4+1 Standard Format: Enter a code in the first digit box:
1–9, 0, B, C, D, E, or F. Enter "# + 10" for 0, "# + 11" for B, "# + 12" for C,
"# + 13" for D, "# + 14" for E, "# + 15" for F.
A "0" (not "# + 10") in the first digit box will disable a report.
A "0" (not "# + 10") in the second digit box (if any) will result in automatic
advance to the next field when programming.
With an Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd
digits) for 1–9, 0, or B–F, as described above.
A "0" (not "# + 10") in the second box will eliminate the expanded message
for that report.
A "0" (not "# + 10") in both boxes will disable the re port.
With Ademco Contact ID Reporting: Enter any digit (other than "0") in
the first box, to enable zone to report This is an "enabling" code only and is
disregarded in the actual reporting to the central office. Entries in the second
boxes will be ignored.
A "0" (not "# + 10") in the first box will disable the report.
Examples:
For Code 3 (Single Digit), enter:
For Code 32 (Two Digits), enter:
For Code B2 (Hexadecimal) enter:
60
TROUBLE REPORT CODE (See box above.)
61
BYPASS REPORT CODE (See box above.)
62
AC LOSS REPORT CODE (See box above.)
Reports with Subscriber No. Timing of this report is random with up to
a 48-minute delay. The Restore report has a random delay of up to about
12 minutes. If AC restores before the report goes out, there is no AC
restore report.
63
LOW BAT REPORT CODE (See box above.)
Reports with Subscriber No.
64
TEST REPORT CODE (See box above.)
Periodic Reports with Subscriber No.
65
OPEN/EXIT ALARM REPORT CODE, 1st DIGITS
Open Report Code : To enable, enter a code (or 0 to disable) in the left-
hand box (see box above).
For expanded or 4+2 reporting, 2nd digit = User #.
Exit Alarm Report Code: To enable, enter a code (or 0 to disable) in
the right-hand box (see box above). If enabled, any alarm from an exit
or interior zone occurring within two minutes after the end of
the exit delay will send a special message indicating exit alarm to the
central station, and a zone indication and "Exit Alarm" or "EA" is
displayed on the keypad.
If an exit or interior zone contains a fault as the exit delay ends,
the local bell and keypad sound continuously.
a)
If the subscriber then disarms the system before the ensuing ENTRY
delay ends, no message is transmitted to the central station, but a
zone indication and "Canceled Alarm" or "CA" is displayed on the
keypad.
b)
If the system is not disarmed before that entry delay ends, a special
message indicating Exit Alarm is sent to the central station and a
zone indication and "Exit Alarm" or "EA" is displayed on the keypad.
For expanded or 4+2 reporting, a 2nd digit is sent, and is the same as the
2nd digit of the zone alarm report code programmed in field 56.
For Contact ID reporting, Event code 374 and the zone number is sent.
There is no restore message for an Exit Alarm report.
– 17 –
3
0
3
2
# + 11
2
(2-Digit Entry)
(2-Digit Entry)
(2-Digit Entry)
(2-Digit Entry)
(2-Digit Entry)
(2-Digit Entry)