ADEMCO VIA-30pse Programming Manual page 18

Hide thumbs Also See for VIA-30pse:
Table of Contents

Advertisement

RESTORE
REPORT CODES
( 70 – 75)
66
AWAY/STAY CLOSE REPORT CODE
(See box on previous page.)
To enable, enter a code (or 0 to disable) in either or both boxes.
For expanded or 4+2 reporting, 2nd digit for each = User # .
67
RF XMTR. LOW BATTERY REPORT CODE
(See box on previous page).
68
CANCEL REPORT CODE
(See box on previous page.)
70
ALARM RESTORE REPORT CODE
(See box on previous page). For expanded or 4+2 reporting, a 2nd digit is
automatically sent, and is the same as the 2nd digit of the zone alarm
report code programmed in field 56.
71
TROUBLE RESTORE REPORT CODE
(See box on previous page). This is sent when a trouble in a zone is
restored.
72
BYPASS RESTORE REPORT CODE
(See box on previous page) . This is sent when a zone that has been
bypassed is un-bypassed.
73
AC RESTORE REPORT CODE
(See box on previous page) . Reports with Subscriber No.
74
LOW BAT RESTORE REPORT CODE
(See box on previous page). Reports with Subscriber No.
75
RF XMTR. LOW BATTERY RESTORE CODE
(See box on previous page). This is sent when a transmitter that
previously sent in a low battery message has sent a message indicating
it no longer has a low battery condition.
80
OUTPUT RELAYS
This is an interactive menu mode that is applicable only if 4229 or 4204
relays are to be used ("2 or 3" in field 25). See the RELAY OUTPUTS
section in the Installation Instructions for a detailed programming
procedure. Also refer to the OUTPUT RELAYS table for field 80 in the
Programming Form in this manual.
81
ZONE LISTS FOR OUTPUT DEVICES
This is an interactive menu mode that is applicable only if field 25 is
programmed for a 4204 or a 4229 relay. Refer to the RELAY OUTPUTS
section in the Installation Instructions for a detailed programming
procedure. Also refer to the ZONE LISTS FOR OUTPUT RELAYS table
for 81 in the Programming Form in this manual.
82
CUSTOM ALPHA EDITING
See the ALPHA DESCRIPTION PROGRAMMING section in the
Installation Instructions for procedure.
83
SEQUENTIAL MODE
May be used to enroll transmitters in a 5800 RF system after all other
zone information has been programmed in 56. See the Installation
Instructions for a detailed programming procedure.
91
OPTION SELECTION
Enter "4" if an Audio Alarm Verification (AAV) unit is connected in the
system (1–3 not used); enter "0" if an AAV unit is not being used.
For UL installations, the AAV option must be disabled (0).
Important : AAV should not be used when Paging or Alarm Reports are
being sent to a Secondary number. If this is done, the call to the
Secondary number by the communicator after the alarm report will
prevent the AAV from taking control of the telephone line, and the AAV
"Listen in" session cannot take place.
–18–
(2-Digit Entry)
(2-Digit Entry)
(2-Digit Entry)
(2-Digit Entry)
(2-Digit Entry)
(2-Digit Entry)
(1-Digit Entry)
(2-Digit Entry)
(2-Digit Entry)