Type 20
Arm–Stay
Type 21
Arm–Away
Type 22
Disarm
Type 23
No Alarm Response
By using a 4281/5881 type RF Receiver and the appropriate 5700/5800 series transmitters,
all of the zone types listed are available for the wireless portion of the system.
This is a special-purpose zone type used with 5800 series wireless pushbutton
units which will result in arming the system in the STAY mode when the
zone is activated. Pushbutton units send zone number as a user number to
central station when arming or disarming.
This is a special-purpose zone type used with 5800 series wireless pushbutton
units which will result in arming the system in the AWAY mode when the
zone is activated. Pushbutton units send zone number as a user number to
central station when arming or disarming.
This is a special-purpose zone type used with 5800 series wireless pushbutton
which will result in disarming the system when the zone is activated.
This is a special-purpose zone type that can be used on a zone when an output
relay action is desired, but with no accompanying alarm (e.g., lobby door
access).