SELECTION of AREA/ROOM or SPOT COOLING

To reduce the temperature of the entire room select 'Area/Room'. For 'targeted' cooling of machinery,
servers, or people etc. select 'Spot Cooling'.
1. If you want to display room temperature,
when air conditioner is operated, push 'cool'
and '▼' button simultaneously for three seconds.
If you want to display spot cooling
temperature,do the same to put it back.

TEMPERATURE CONTROL OPERATION

1. When power is ON, the setting temperature is displayed.
Default of setting temperature is as below.
·50℉ in Spot Mode. ·60℉ in Room Mode.
3. The display showing the set temperature will
blink 3 times.
2. If you want to change temperature unit ℉ ↔ ℃,
when air conditioner is stopped, push ▼ and ▲
button simultaneously for three seconds.
2. When you push either ▼ or ▲ button, the setting
temperature is changed.
Mode
Display range
Room Temp
Spot Temp
Cooling operates when Room/Spot temperature is
higher than set temperature.
Cooling stops when Room/Spot temperature is
lower than set temperature.
Setting range
32℉~99℉
60℉~86℉
32℉~99℉
50℉~86℉