External Remote Terminal 2 - Mitsubishi Electric CP910E Operation Manual

Table of Contents

Advertisement

EXTERNAL REMOTE TERMINAL 2

The image can be stored in memory and printed by sending the remote signal through
the external remote terminal on the rear panel.
Make out the necessary circuit to use this function by referring to the following.
2 2 2 2 2 EXTERNAL REMOTE TERMINAL SIGNAL ALLOCATION (MINI
DIN8PIN)
Pin No.
Function
1
Ground
2
MEMORY
3
BUSY2
4
BUSY1
5
PRINT
6
REMOTE
7
Unused
8
DC3V
When the signal from BUSY terminal is received with TTL level, keep the following.
| I
| = 2mA or less, | I
OL
| I
| means the current flowing into the unit at Low output, | I
OL
current flowing out of the unit at High output.
Just after completing printing, there is a period that memory signal is not accepted.
2 2 2 2 2 PIN NO. 6 6 6 6 6 REMOTE TERMINAL
By sending the following remote control codes from pin No.6, the same functions as the wired
remote control unit supplied can be controlled.
01: [ button
02: ] button
08: PRINT Q'ty { button
0A*: MENU button
0D*
12*: PROGRAM button
16*: COLOR ADJUST button
1C*: MEMORY PAGE button
In case of the codes with * mark, 5 words are sent.
2 2 2 2 2 TIMING CHART
Input signal level
:
Input timing
:
≥ 0.4ms
T
1
1.5ms < T
2ms < T
13ms < T
Description
Earth
Memory : When the signal becomes "LOW" from "HIGH", the
image is stored in memory. (When the signal has
been "LOW" for 15ms or more, the image is stored
in memory.) See page 42, 43.
Refer to the BUSY LEVEL setting of REMOTE SET in
SERVICE MENU. See page 43.
Refer to the BUSY LEVEL setting of REMOTE SET in
SERVICE MENU. See page 43.
When the signal becomes "LOW" from "HIGH", the stored
image is printed. (When the signal has been "LOW" for 15ms
or more, the image is printed.)
The same functions as the supplied remote control can be
controlled.
Power supply for the remote control DC 1mA Max.
| = 1mA or less
OH
03: } button
09*
0B*: CLEAR button
0E*: SET button
13*: PRINT button
17*: MEMORY button
1D*: MONITOR button
TTL
1 word 38.4 ms (reference)
< 2ms
2
< 4.2ms
3
< 90ms
4
| means the
OH
04: { button
0C: PRINT Q'ty } button
0F*: STOP button
15*: FIELD/FRAME button
18*: DISPLAY button
(The above values are references.)
1
1
(EXAMPLE) Print code
1
2
3
4
6 7 8
Pin No.
Circuit inside the VCP
DTC124EK
To VCP
22kΩ
22kΩ
DC5V
74LVC125
10kΩ
100Ω
From VCP
TTL level
DC5V
74LVC125
10kΩ
100Ω
To VCP
TTL level
1kΩ
To VCP
56kΩ
1.6 ms (T
)
2
0.4 ms (T
)
1
3.2 ms (T
)
3
0.4 ms (T
)
1
T 4
0
0
1
0
1 word
= 13 = 0 1 0 0 1 1
5
DC5V
10kΩ
100Ω
2
MEMORY
3
BUSY2
4 BUSY1
5
PRINT
6
REMOTE
27

Advertisement

Table of Contents
loading

Table of Contents