TsTbM-rrs--TW-a
Once in the Tech Setup Menu, the
features while the
+
setting. The
button does not change the value and will take you to
the next feature. Only the
Tech setup steps
Zone
Selects which zone is
used for connecting to the
selection
TSTBM3H2CPH6W-A.
Only 1 remote can be used
for each zone for a total of 4
remotes.
remote
Selects a Name for the remote.
This name will appear on the
name
TSTBM3H2CPH6W-A when
the TSTBM3H2CPH6W-A
is displaying the remote's
temperature.
show set
Enabling this feature
will allow the remote to
temporarily override the
TSTBM3H2CPH6W-A set point.
room
This feature allows the
installer to change the
Temperature
calibration of the room
Calibration
temperature display. For
example, if the thermostat
reads 70° and you would like it
to read 72° then select +2.
f or C
This feature sets the
display temperature to
read in either Fahrenheit or
Celsius.
low
This feature allows you
to set a minimum cool
Temperature
setpoint value. The
setpoint
setpoint temperature
limit
cannot be lowered
below this value.
high
This feature allows you to set a
maximum heat setpoint value.
Temperature
The setpoint temperature
setpoint
cannot be raised
limit
above this value.
6 720 220 377
+
button rotates through the setup
button changes the values for that particular
button will change the value.
lCD will
show
Subject to change without prior notice
Technician setup Menu
adjustment Options
Zone 1
Zone 2
Zone 3
Zone 4
The Zone number on the
TSTBM-RRS--TW-A and the
TSTBM3H2CPH6W-A must match in
order to establish a connection.
Remote 1, Remote 2,
Remote 3, Remote 4,
Bedroom 1, Bedroom 2,
Bedroom 3, Bedroom 4,
Kitchen, Living Room, Hall, Family
Room, Dining Room, Offi ce, Study,
Den, Loft, Upstairs.
N—The remote is used as a sensor only
and cannot change the current set
point.
Y—Enables the temperature adjustment
keys allowing the user to temporarily
override the TSTBM3H2CPH6W-A set point
with the TSTBM-RRS--TW-A remote.
You can adjust the room temperature
display to read
-4°F to +4°F above or below the
factory calibrated reading.
F for Fahrenheit
C for Celsius.
k
Use the
ey to select the minimum
cool setpoint.
Use the
key to select the maximum
heat setpoint.
factory
Default
settings
ZONE 1
REMOTE
1
N
0
F
44ºF
90ºF
Revised 02-13