Parameter menu
Vacuum pre-feed *
Vacuum run-on *
* WXD2 only
In order to prevent the pump from starting prematurely or to ensure
a defined soldering-joint preheating time, it is possible to set an ON
delay.
Option
Description
0 sec
OFF: vacuum pre-feed function is OFF (factory
setting)
1-10 sec
ON: vacuum pre-feed time, individually
To prevent the desoldering iron from becoming clogged, it is possible
to set a vacuum run-on time.
Option
Description
0 sec
OFF: vacuum run-on function is OFF (factory
setting)
1-10 sec
ON: vacuum run-on time, individually adjustable