Parameter menu
Standby temperature
Standby time (temperature deactivation)
AUTO OFF time (automatic switch-off time)
Sensitivity
Note The soldering tools have a usage detector (sensor) in the hand-
le which automatically starts the cooling cycle when the soldering
tool is not in use.
The standby temperature is automatically set after a temperature
deactivation.
When the soldering tool is not in use, the temperature is reduced
to the standby temperature after the set standby time has elapsed.
Standby mode is indicated as a flashing actual value and the display
reads „Standby".
Press control key to exit Standby mode. The sensor integrated tool
detects the change in state and deactivates Standby mode as soon
as the tool is moved.
Option
Description
OFF
standby time is deactivated (factory setting)
1-99 min
standby time, individually adjustable
Note
In the case of soldering work with low heat requirements, the
reliability of the standby function may be impaired.
When the soldering tool is not in use, the soldering tool heater is
switched off when the AUTO OFF time expires.
Temperature deactivation is performed independently of the set
standby function. The actual temperature is indicated by flashing
LED and serves as a residual heat display. The display reads „OFF".
Option
Description
OFF
AUTO OFF function is deactivated (factory setting)
1-999 min AUTO-OFF time, can be set individually.
Option
Description
low
Non-sensitive – Reacts to heavy (long) movement
normal
standard (factory setting)
high
Sensitive - Reacts to light (short) movement