Environmental
Table 1–2 describes the environmental specifications for your
Specifications
system.
Table 1–2 Environmental Specifications
Specification
Operating temperature
Relative humidity
(noncondensing)
Max heat dissipation
Minimum operating clearance
Max operating altitude
Max power consumption
Operating voltage range
(single phase)
Operating frequency range
Power cord length
Declared operating acoustic
level
Environmental and Power Requirements
Single power supply
Dual power supply
Front
Rear
Single power supply
Dual power supply
Measurement
10-35° C (50-95° F)
20-80%
880 W, 3005 Btu/hr
1280 W, 4371 Btu/hr
75 cm (29.5 in)
15 cm (5.9 in)
2000 m (6562 ft)
880 W
1280 W
100 VAC to 120 VAC/220 VAC to
240 VAC
47 Hz to 63 Hz
2.4 m (8 ft)
LNPEc (BELs)=6.6 max per ISO
7779
Basic Operation 1–7