Kranzle 2170TST Operating Manual page 13

Table of Contents

Advertisement

T T T T T ransmission unit
ransmission unit
ransmission unit
ransmission unit
ransmission unit
32
Pr
Preparation for use
Pr
eparation for use
eparation for use
eparation for use
Pr
Pr
eparation for use
When using cleansing agents:
Place chemical filter no. 5 in the reservoir with the cleansing agent. Turn on Vario-Jet No.4 to
to enable the injector to induct the cleansing agent. By turning back the Vario-Jet nozzle, the
supply of chemical is automatically cut off. Allow the cleansing agent to take effect and then
remove with high pressure spray.
A mixing ratio of 3-5% is achieved
when the Vario-Jet is fully turned
on. pH value neutral 7-9.
Note that you must always
comply with the instructions
provided by the manufac-
turer of the cleansing agent
(e.g. instructions concern-
ing safety clothing) and the
water protection regula-
tions!
To shut down the pump:
1.
Switch off the machine.
2.
Cut off the water supply.
3.
Open the spray gun briefly until the pressure is released.
4. Apply the safety catch on the spray gun.
5. Remove the water hose and spray gun.
6. Drain the pump: switch on the motor for approx. 20 seconds.
7. Pull the plug from the socket.
8. Winter: store the pump in rooms above 0 °C.
9. Clean the water filter.
13

Advertisement

Table of Contents
loading

Table of Contents