6. MULTIPLE REMOTE CONTROL DISPLAY
You can control several units with a multiple remote control display,by
wiring an optional multiple display adapter (PAC-SA88HA-E) with relays
and lamps on the market.
6-1 How to wire
(1) Connect the multiple display adapter to the connector CN51 on the
indoor controller board.
(2) Wire three of the five wires from the multiple display adapter as shown
in the figure below.
<Wiring >
5
CN51
1
connector(5P)
RED
BROWN
Optional multiple display
adapter
The maximumdistance between
indoor board and relay is 33ft.
[Notes on Signs]
X1:Relay (for check lamp)
X2:Relay (for operation lamp)
RL:Check Lamp
GL:Operation Lamp
[Field supplied parts]
Relays:12V DC with rated coil power con-
sumption below 0.9W.
Lamps:Matching to power supply voltage.
<Wiring diagram>
RL-1
Power
GL-1
supply
RL-2
GL-2
RL-3
GL-3
Multiple Remote Control Display

7. AUTO RESTART FUNCTION

By setting the dip switch SW1-10 to ON for PK12 and cutting to the jumper wire J1-10 for PK18/24/30/36, the air condition-
er can be started/stopped by power supply ON/OFF.
If the air conditioner is OFF before the power failure, it will not start operation by power restore.
•This function is mainly to emergency performance when the power supply stops temporarily. Therefore, since the protec-
tion function (for example, crank case heater and prevention from restarting in 3 minutes, etc.) of the device is not operat-
ed, this function should not be used mostly.
8. TIMER OPERATION OR THE OPERATION BY AN EXTERNAL SIGNAL
<Wiring>
A
B
Brown
Red
For remote control, connect the optional timer adapter (PAC-SA89TA-E)
GREEN
X1
YELLOW
X2
ORANGE
Electrical insulation is needed.
Wiring at the actual place
X1-1
X2-1
X1-2
X2-2
X1-3
X2-3
A
B
Brown
Red
Orange
Orange
Remote controller
OC196A-55
RL
X1
X2
GL
Power
supply
<System>
3wires
Power
3wires
supply
3wires
2wires
Multiple remote control
Remote
ON-OFF display
controller
(Field supply)
(Operation check)
X1
X2
X1
X2
X1
X2
Relay box
A : an optional timer adapter
B : a single-throw switch
Remote controller
Indoor controller board
No.1 unit
No.2 unit
Remote
Relay box
controller
(Field supply)
cable
Remote
controller
Multiple remote
controller adapter
1
No.1 unit
5
1
No.2 unit
5
1
No.3 unit
connect to
5
the connector CN51
CN51
No.3 unit
Remote
controller

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents