Operation Without Dmx Controller - IMG STAGE LINE LSX-40G Instruction Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
originally intended, if it is not correctly installed or con-
nected or operated, or not repaired in an expert way.
G
Important for U. K. Customers!
The wires in this mains lead are coloured in accord -
ance with the following code:
green/yellow = earth
blue = neutral
brown = live
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured mark-
ings identifying the terminals in your plug, proceed as
follows:
1. The wire which is coloured green and yellow must
be connected to the terminal in the plug which is
marked with the letter E or by the earth symbol
or coloured green or green and yellow.
2. The wire which is coloured blue must be connected
to the terminal which is marked with the letter N or
coloured black.
3. The wire which is coloured brown must be con-
nected to the terminal which is marked with the let-
ter L or coloured red.
Warning – This appliance must be earthed.
If the unit is to be put out of operation defini-
tively, take it to a local recycling plant for a dis-
posal which is not harmful to the environment.
3 Applications
These laser effect units are capable of projecting differ-
ent geometric figures onto a surface or into an artificial
fog either independently or music-controlled via a micro-
phone or by a DMX control. They can be used e. g. on
stage or in discotheques.
For operation via a DMX controller, the models
LSX-40G and LSX-80R are equipped with 8 DMX chan-
nels and the model LSX-120RG with 9 DMX channels.
4 Mounting and Setting into Operation
The laser must safely be mounted in an expert way. The
person who sets up the unit together with all additional
components (e. g. mirror, lenses, projection area) to cre-
ate a laser system, becomes the legitimate manufac-
turer of this system. Observe in any case the warning
notes in chapter 2.1.
WARNING 1. According to international safety regu-
lations the laser must be installed so
that the laser beam has a minimum dis-
tance of 3 m to the floor when persons
stand or sit under the beam (fig. 3).
However, the unit can also be installed
so that in the horizontal plane the laser
beam keeps a minimum distance of
2.5 m to persons (fig. 4).
2. As the safety regulations are different in each coun-
try, the regulations of the country where the unit will
be operated must be observed in any case.
3. Select the mounting location so that a sufficient air
circulation will be ensured during operation. The unit
must have a minimum distance of 50 cm to adjoining
surfaces and the air vents at the housing must not
be covered in any case.
4. If the laser is installed at a place where people may
stand or sit under, it must additionally be secured
(e. g. by a safety rope at the mounting bracket; fix
the safety rope so that the maximum falling distance
of the unit does not exceed 20 cm).
1) Tightly screw the laser with the mounting bracket (1) to
,
a suitable place, e. g. with a stable mounting screw or a
support for lighting units (C hook) at a cross bar.
2) To align the unit, release the two setscrews (2) at the
mounting bracket. Adjust the desired inclination of the
unit and retighten the screws.
3) Connect the supplied mains cable to the mains jack
(12) first and then to a socket (230 V~/ 50 Hz).
4) Switch on the laser with the mains switch (14). The red
LED POWER (3) lights up as a power indication.
5) To switch on the laser beam, connect the supplied
key to the lock of the switch (11) and turn the key to
position ON.
IMPORTANT! The laser system must not be oper-
ated without the presence of a laser protection
adviser. In case of absence, this advisor should
have secured the laser beam with the key switch
against unauthorized operation.
Hint: If the laser beam is guided through a fog (gener-
ated artificially), fantastic, three-dimensional light effects
are created. A great selection of fog machines can be
found in the product range of "img Stage Line".

5 Operation without DMX controller

For automatic run of the laser through its show pro-
gramme without DMX controller, the display (6) must
show
:
1) Press the button FUNC (5) so many times until the
display shows
on the display is shown in fig. 5 on page 3.
2) Memorize the selection of the functions with the but-
ton ENTER so that the unit also operates in the
selected mode after switching-on the next time. The
display confirms the storage by the indication
lighting up three times.
3) The laser may also be controlled by the beat of the
music picked up by the integrated microphone (10).
For this purpose press the button FUNC so many
times until the display shows
function with the button ENTER.
Adjust the control (9) for the microphone sensitiv-
ity so that the laser beam is controlled in an optimum
way by the music. With each control signal created by
. The sequence of the indications
. Memorize the
GB
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lsx-80rLsx-120rg

Table of Contents