Settings Overview - Danfoss ECL Comfort 210 Installation Manual

Hide thumbs Also See for ECL Comfort 210:
Table of Contents

Advertisement

Installation Guide

4.0 Settings overview

It is recommendable to make a note of any changed settings in the empty columns.
Setting
Heat curve
Temp. max. (flow temp. limit, max.) — A231.1 / A331.1
Temp. min. (flow temp. limit, min.)
Heat curve
Temp. max. (flow temp. limit, max.) — A231.2 / A331.2
Temp. min. (flow temp. limit, min.)
High supp. T X2 (high value of supply temp.) — A231.2 / A331.2 11300
High T max Y2 (high value of max limitation) — A231.2 / A331.2 11301
Low supply T X1(low value of supply temp.) — A231.2 / A331.2 11302
Low T max Y1 (low value of max limitation) — A231.2 / A331.2
High T out X1 (return temp. limitation, high limit, X-axis)
Low limit Y1 (return temp. limitation, low limit, Y-axis)
Low T out X2 (return temp. limitation, low limit, X-axis)
High limit Y2 (return temp. limitation, high limit, Y-axis)
Infl. - max. (return temp. limitation - max. influence)
Infl. - min. (return temp. limitation - min. influence)
Adapt. time (adaptation time)
Priority (priority for return temp. limitation)
High T out X1 (flow / power limitation, high limit, X-axis)
Low limit Y1 (flow / power limitation, low limit, Y-axis)
Low T out X2 (flow / power limitation, low limit, X-axis)
High limit Y2 (flow / power limitation, high limit, Y-axis)
Adapt. time (adaptation time)
Filter constant
Input type, A231
Input type — A331
Units — A231
Units — A331
Auto saving (saving temp. dependent on outdoor temp.)
Boost
Ramp (reference ramping)
Optimizer (optimizing time constant)
Pre-stop (optimized stop time)
Total stop
Cut-out (limit for heating cut-out)
Motor pr. (motor protection)
Xp (proportional band)
Tn (integration time constant)
M run (running time of the motorized control valve)
Nz (neutral zone)
Chan.-over time (change-over time)
Danfoss District Energy
ECL Comfort 210 / 310, application A231 / A331
ID
11178
11177
11177
11303
11031
11032
11033
11034
11035
11036
11037
11085
11119
11117
11118
11116
11112
11113
11109
11109
11115
11115
11011
11012
11013
11014
11026
11021
11179
11174
11184
11185
11186
11187
11314
Page
Factory settings in circuit(s)
1
2
55
56
90 °C
56
10 °C
57
58
58
10 °C
58
150 °C
58
95 °C
59
70 °C
59
50 °C
60
15 °C
60
40 °C
60
-15 °C
61
60 °C
61
0.0
61
0.0
61
25 s
62
OFF
63
15 °C
999.9
64
l/h
64
-15 °C
999.9
64
l/h
64
OFF
64
10
65
OFF
65
OFF
65
l/h
65
l/h
66
-15 °C
66
OFF
67
OFF
67
OFF
68
ON
68
OFF
69
20 °C
70
OFF
70
80 K
70
30 s
70
50 s
71
3 K
72
5 s
VI.LG.P1.02
3
DEN-SMT/DK
53