Additional documentation

In addition to this document, you will need the following documents, which are available at
www.hp.com/support/manuals. On the Manuals page, clock Servers > ProLiant ml/dl and tc
series servers.
For file serving node procedures, select HP Proliant DL380 G6 Server series or HP Proliant DL380
G7 Server series. The following documents contain the replacement procedures:
HP ProLiant DL380 G6 Server Maintenance and Service Guide
HP ProLiant DL380 G7 Server Maintenance and Service Guide
For X9300 Management Server procedures, select HP Proliant DL360 G6 Server series or HP
Proliant DL360 G7 Server series. The following documents contain the replacement procedures:
HP ProLiant DL360 G6 Server Maintenance and Service Guide
HP ProLiant DL360 G7 Server Maintenance and Service Guide
Repair procedures for the X9300 controller and drive enclosure are available in the Service and
maintenance information section on the HP StorageWorks P2000 G3 MSA Array Systems or HP
StorageWorks 2000fc G2 Modular Smart Array Manuals page. To locate the documents, go to
http://www.hp.com/support/manuals, In the storage section, click Disk Storage Systems,and then
under P2000/MSA Disk Arrays, click HP StorageWorks P2000 G3 MSA Array Systems or HP
StorageWorks 2000fc G2 Modular Smart Array.

Replacing a system board

To replace a system board on a file serving node or the X9300 Management Server:
1.
If the server is an X9300 Management Server, skip this step. If the server is a file serving node,
fail over the server to its standby server using the management console GUI or CLI:
On the GUI, select Servers from the Navigator pane, and then select the appropriate
server from the Servers pane. Next, select the server name in the left pane, and click
Failover.
On the CLI, execute the following command, where server_name is the server containing
the board:
ibrix_server -f -h <server_name>
2.
Power down the server.
3.
Replace the system board: For a file serving node, see the HP Proliant DL380 G6 Server
Maintenance and Service Guide. For an X9300 Management Server, see the HP Proliant
DL360 G6 Server Maintenance and Service Guide.
4.
Power on the server.
a.
Check the MAC address of the new NIC. Use the ifdown eth(n) command, and then
use the ip addr command.
b.
Change the HWADDR= line in the relevant ifcfg-eth(n) file to be the MAC address
from the previous step.
c.
Follow this procedure for every NIC that was affected by the physical board swapout
(for example, if this was a dual NIC, then two files need to be updated).
d.
Restart the network subsystem with service network restart.
e.
Run the following command to verify that all is correct
cat /proc/net/bonding/bond(n)