Restoring The Node Configuration; Completing The Upgrade - HP StorageWorks x9300 Administrator's Manual

Hide thumbs Also See for StorageWorks x9300:
Table of Contents

Advertisement

5.
When the following screen appears, enter qr to install the X9000 software on the file serving
node.
The server reboots automatically after the software is installed. Remove the DVD from the
DVD-ROM drive.

Restoring the node configuration

Complete the following steps on each node, starting with the previous active management console:
1.
Log in to the node. The configuration wizard should pop up. Escape out of the configuration
wizard.
2.
Attach the external storage media containing the saved node configuration information.
3.
Restore the configuration. Run the following restore script and pass in the tgz file containing
the node's saved configuration information as an argument:
/usr/local/ibrix/setup/restore <saved_config.tgz>
4.
Reboot the node.

Completing the upgrade

Complete the following steps:
1.
Remount all X9000 Software file systems:
<ibrixhome>/bin/ibrix_mount -f <fsname> -m </mountpoint>
2.
Remount all previously mounted X9000 Software file systems on Windows X9000 clients using
the Windows client GUI.
3.
If automated failover was enabled before the upgrade, turn it back on from the node hosting
the active management console:
<ibrixhome>/bin/ibrix_server -m
72
Upgrading the X9000 Software

Hide quick links:

Advertisement

Table of Contents
loading