Command Feedback
The COMM module provides feedback to the main program for switcher changes via string events. The
strings supported are listed below.
PLEASE NOTE: Feedback is only provided when there is a state change. If no state change resulted
from the command sent in, then no feedback will be returned.
String
DEBUG=<value>
SWITCH=<input>
VERSION=<version>
Device Notes
The supported device is the Extron IN1508.
Programming Notes
By default the number of inputs is 8 and the number of outputs is 1.
This module de-queues commands to the device at a regular interval of 200 milliseconds and also
de-queues when valid response is received.
Professional Control Solutions LLC 3804 Parchment Circle Richmond, VA 23233-7034
Returns the state of debugging messages in the UI module
and the Comm. module.
<value> : 0 = all messages off
1 = set all messages on
DEBUG=1
Reports the input channel that is currently connected to
the output channel.
the CL= command being successfully executed or in
response to the SWITCH= command.
<input>
: 0
1..8 = input channel
SWITCH=1
Reports the version number of the module.
<version> : x.y.z = module version number
VERSION=1.0.0
Table 5 - Command Feedback Definitions
804-364-3809 PCS_LLC@comcast.net
Description
This string is sent in response to
= no input channel connected
7