Regency I31-NG3 Owners & Installation Manual

I31-3 gas inbuilt
Hide thumbs Also See for I31-NG3:

Advertisement

Quick Links

Owners &
Installation
LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553, NZS 5262 and
have been certified by the Australian Gas
Association for installation and operation as
described in these Installation and Operating
Instructions.
Your unit should be serviced annually by
an authorised service person.
I31-3 Gas Inbuilt
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional in-
formation consult an authorised installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flam-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
918-001f
Model:
I31-NG3
I31-LPG3
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electrical
switch: do not use any phone
in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your gas
supplier, call the fire depart-
ment.
04/08/15

Advertisement

Table of Contents
loading

Summary of Contents for Regency I31-NG3

  • Page 1 Owners & Installation I31-3 Gas Inbuilt Model: I31-NG3 I31-LPG3 PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, altera- What to do if you smell gas: tion, service or maintenance can cause Do not try to light any appli- injury or property damage.
  • Page 2: Unit Dimensions

    GAS FIREPLACE INBUILT FIREPLACE TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Inbuilt Fireplace by Regency Industries. The Regency Gas Fireplace Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch. The model I31-3 of this series has been approved by Australian Gas Association for both safety and efficiency.
  • Page 3: Table Of Contents

    - Bay Louvres ............11 Hampton Cast Faceplate Installation......12 Warranty ............... 26 Hampton Cast Grill Installation ........13 Barossa Curved Front ..........14 Optional Remote Control .......... 15 Optional Wall Thermostat .......... 15 Wiring Diagram ............15 Regency I31-3 Gas Fireplace Inbuilt...
  • Page 4: Safety Label

    DATA BADGE DATA BADGE NOTE: Regency units are con- This is a copy of the label that accompanies stantly being improved. Check the label on the each Regency I31-3 Gas Inbuilt fireplace. We unit and if there is a difference, the label on the have printed a copy of the contents here for unit is the correct one.
  • Page 5: Installation

    CHECKLIST Note: This unit is equipped with a heat sen- BEFORE YOU START The Regency Gas Insert is installed as listed sor thermodisc which will prevent the below. blower from operating until the unit Installation is to be carried out ONLY by an reaches the correct temperature.
  • Page 6: Minimum Fireplace Dimension

    DIMENSIONS GAS CONNECTION WARNING: Only persons licensed to work with The minimum fireplace dimensions for the Regency gas space heater are shown in the gas piping may make the necessary following diagrams: gas connections to this appliance. 1) If the appliance is to be installed into an existing chimney system, thoroughly clean the masonry or factory built fireplace.
  • Page 7: Draft Diverter Connection

    3.6 m. is recommended. house. The Regency Inbuilt Fireplace incorporates its own internal draft diverter, so no additional 2) Light the unit and set controls to maximum. external draftdiverter is required.
  • Page 8: Optional Brick Panel

    OR DISCONNECT THIS SWITCH. Diagram 2 Vermiculite and Vermiculite and Vermiculite and embers. embers. embers. 3) Place Rear Log A)02-43 on the two pins on the rear log support. Diagram 3 Regency I31-3 Gas Fireplace Inbuilt...
  • Page 9 Logs A)02-43, C)02-56, and B)02-45 in position C)02-56 B)02-45 6) Place the Left Top Log D)02-46 on the pin B)02-45 on Log C)02-56 and on top of the cutout G)02-44 on Log A)02-43. Bracket Notch Regency I31-3 Gas Fireplace Inbuilt...
  • Page 10: Faceplate & Trim

    10) Attach the faceplate panels* to the inbuilt fireplace body using the 4 remaining black screws. See diagram 5. Diagram 2 11) Push the Regency logo plate into the two Rear View: Trim Assembly holes in the bottom left corner of the face- plate. See diagram 4.
  • Page 11: Flush Louvres

    Note: The top and if the louvre needs to be adjusted; bend the bottom trim pieces bracket out as shown in the diagram. are different, check diagrams above and below. 3) Install top and bottom louvres. Regency I31-3 Gas Fireplace Inbuilt...
  • Page 12: Hampton Cast Faceplate Installation

    Attach the clip to the rear of the faceplate to ensure that the wires do not touch the side of the unit. 10) The power cord should be run behind the faceplate panel. 28" Regency I31-3 Gas Fireplace Inbuilt...
  • Page 13: Hampton Cast Grill Installation

    Secure using 2 screws per hinge. 13) To put on the Regency logo, peel the sticker from the back of the logo and place it centered on the bottom left hand corner of the faceplate.
  • Page 14: Barossa Curved Front

    3. 2) Pull down louver. 3) Fix brackets onto firebox, one on each side using 1 screw per side. Secure with screw. Secure bracket 6) Close louver. with screw. Regency I31-3 Gas Fireplace Inbuilt...
  • Page 15: Optional Remote Control

    OUT Pressure Tap Piezo Ignitor Yellow Burner White Orange Brown Red/Black Pilot Stripe Robertshaw Valve Flue Spill Pressure Thermo- Switch couple Thermostat (Auto Reset) (Normally closed) Remote (Optional) Receiver (Millivolt) Remote Transmitter (Optional) (Optional) (Millivolt) Regency I31-3 Gas Fireplace Inbuilt...
  • Page 16: Operating Instructions

    2) Open the bottom louvre assembly. Blower: 3) Push in the gas control knob slightly and Regency gas appliances use high tech blowers turn clockwise to "OFF". Do not force. to push heated air farther into the room. It is not unusual for the fan to make a "whirring"...
  • Page 17: Copy Of Lighting Instruction Plate

    The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint (not with wall paint). Regency uses StoveBrite Paint - Metallic Black #6309. 3) Make a periodic check of burner for proper position and condition.
  • Page 18: Maintenance

    REPLACEMENT contact with the rear burner or thermopile. OR GUARD REMOVED FOR SERV- ICING AN APPLIANCE MUST BE Your Regency stove is supplied with high tem- REPLACED PRIOR TO OPERATING perature, 5 mm Neoceram ceramic glass that THE APPLIANCE. will withstand the highest heat that your unit will produce.
  • Page 19: Glass Gasket

    Power cord ground wire HIGH Yellow/Green Brown r washer 240V AC (Live) Ground 50 HZ Black White Pilot Fan Thermodisc Assembly (Normally open) Thermocouple IN Pilot OUT Pressure Tap Piezo Ignitor Regency I31-3 Gas Fireplace Inbuilt Yellow Burner White Orange Brown...
  • Page 20: Trouble Shooting

    MAINTENANCE TROUBLE SHOOTING REGENCY GAS SPACE HEATER SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION 1) Thin black coating [soot]forms on view- a) Incorrect gas pressure Check and correct gas pressure if sooting ing glass. b) Not enough combustion continues open aeration shutter on burner.
  • Page 21: Parts List

    13) * Levelling Bolts 5/16 x 3 Hex Head 36) 400-090 Brick Clips 948-216 Logo Plate 38) 402-046 Glass Support Trim - Black 918-001 Manual - Regency 159) 936-233 3/4" Rope Gasket *Not available as a replacement part. Regency I31-3 Gas Fireplace Inbuilt...
  • Page 22 87) 910-341 Thermopile 902-267 Rear Log 902-231 Left Top Log 902-232 Center Log 902-226 Middle Right Log 902-230 Middle Left Log 902-229 Front Right Log 902-228 Front Left Log *Not available as a replacement part. Regency I31-3 Gas Fireplace Inbuilt...
  • Page 23: Faceplate Assembly

    Faceplate & Trim Compelte - Oversize 141) * Faceplate Side Right - Oversize *Not available as a replacement part. 142) * Faceplate Top - Oversize 143) * Faceplate Side Left - Oversize 401-524 Trims Packaged - Oversize Regency I31-3 Gas Fireplace Inbuilt...
  • Page 24 Bay Door Trim Set - Steel 160) 403-927 Barossa Curved Front 111) * Bay Door Trim Top 112) 904-196 1" Round Ceramic Magnet *Not available as a replacement part. 113) * Bay Door Trim Bottom Regency I31-3 Gas Fireplace Inbuilt...
  • Page 25 Flush Glass Frame 194) * Mounting Flange 207) 402-981 Cast Grill (Set) - Top & Bottom - Black Metallic 402-986 Cast Grill (Set) - Top & Bottom - Black Enamel *Not available as a replacement part. Regency I31-3 Gas Fireplace Inbuilt...
  • Page 26: Warranty

    Regency shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency Fireplace Products.
  • Page 27 03 97997277 NOTE: PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES. Regency I31-3 Gas Fireplace Inbuilt...
  • Page 28 Register your Regency warranty online ® www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

This manual is also suitable for:

I31-lpg3

Table of Contents