Hilti SD 6000 Operating Instructions Manual page 21

Hide thumbs Also See for SD 6000:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
Power tool
Rated voltage / rated cur-
rent
Mains frequency
Weight in accordance
with EPTA procedure
01/2003
Dimensions (L x W x H)
Rated speed under no
load
Max. torque
Chuck
Claw coupling
Vibration-absorbing grips
Other information about the power tool
Speed control
Forward / reverse
Protection class as per EN
NOTE
The vibration emission level given in this information sheet has been measured in accordance with a standardised test
given in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment
of exposure. The declared vibration emission level represents the main applications of the tool. However if the tool is
used for different applications, with different accessories or poorly maintained, the vibration emission may differ. This
may significantly increase the exposure level over the total working period. An estimation of the level of exposure to
vibration should also take into account the times when the tool is switched off or when it is running but not actually
doing the job. This may significantly reduce the exposure level over the total working period. Identify additional safety
measures to protect the operator from the effects of vibration such as: maintain the tool and the accessories, keep
the hands warm, organisation of work patterns.
Noise and vibration information (measured in accordance with EN 60745‑2‑2):
Wear ear protection!
Typical A-weighted sound power level, SD 2500
Typical A-weighted sound power level, SD 5000
Typical A-weighted sound power level, SD 6000
Typical A-weighted emission sound pressure level, SD
2500
Typical A-weighted emission sound pressure level, SD
5000
Typical A-weighted emission sound pressure level, SD
6000
Uncertainty for the given sound level
Triaxial vibration values (vibration vector sum)
Screwdriving without impact action, SD 2500, a
Screwdriving without impact action, SD 5000, a
SD 6000
Rated voltage 110 V:
6.9 A
Rated voltage 220 V:
3.4 A
Rated voltage 230 V:
3.3 A
Rated voltage 240 V:
3.1 A
50...60 Hz
1.4 kg
275 mm x 77 mm x
170 mm
0...6,000/min
7.9 Nm
Hex. socket ¹⁄₄"
With "jet" action for quiet
operation
x
h
h
SD 5000
Rated voltage 110 V:
6.9 A
Rated voltage 220 V:
3.4 A
Rated voltage 230 V:
3.3 A
Rated voltage 240 V:
3.1 A
50...60 Hz
1.4 kg
275 mm x 77 mm x
170 mm
0...5,000/min
9.5 Nm
Hex. socket ¹⁄₄"
With "jet" action for quiet
operation
x
Electronic, by way of the control switch
Switch with interlock to prevent switching while running
Protection class II (double insulated) as per EN 60745‑1
100 dB (A)
98 dB (A)
96 dB (A)
89 dB (A)
87 dB (A)
85 dB (A)
3 dB (A)
2.5 m/s²
2.5 m/s²
SD 2500
Rated voltage 110 V:
6.9 A
Rated voltage 220 V:
3.4 A
Rated voltage 230 V:
3.3 A
Rated voltage 240 V:
3.1 A
50...60 Hz
1.5 kg
310 mm x 77 mm x
170 mm
0...2,500/min
19 Nm
Hex. socket ¹⁄₄"
With "jet" action for quiet
operation
x
17
en

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sd 2500Sd 5000