Unpacking and Preparing the Machine for Operation
YOUR MODEL 3366XP POWER SWEEPER HAS BEEN SHIPPED COMPLETE, BUT DO NOT ATTEMPT TO
OPERATE WITHOUT READING THE FOLLOWING INSTRUCTIONS.
1. Uncrate the machine and carefully remove from skid to prevent damage.
2. Connect and tighten battery cables.
3. Fill tank with UNLEADED gasoline or Diesel Fuel.
Never fill fuel tank while the engine is running. Always be sure gasoline container and sweeper are electrically
connected before pouring gas. This can be easily done by providing an insulated wire (permanently attached to
4. Check engine crankcase oil level. Although properly lubricated at factory, check before starting
engine. No special break-in oil is used and recommended number of operating hours before the
initial oil change is the same as normal. See Maintenance chart.
5. Check radiator coolant level. Permanent type antifreeze is added at the factory to provide protection
to approximately -35° F (-37° C). To retain this protection level, always add 1/2 part water to 1/2 part
antifreeze.
6. Check oil level in the hydraulic reservoir located at center of machine beside the engine. The
hydraulic reservoir is full, if oil can be seen in the sight glass with the hopper in "DOWN" position.
If oil is required, add HYDRAULIC FLUID ONLY, automatic transmission fluid FORD type "F" ATF.
After the first 50 operating hours, service must be performed on your engine to insure future high performance
American-Lincoln
3366XP
C1033
FIGURE 1
WARNING
the container) with battery clip on the other end.
NOTE
and trouble free operation. See Maintenance.