9 - USER PROGRAMMING

Without entering technical programming it is possible
to set the amount dispensed for each type of dispens-
ing; it is also possible to display the quantity of doses
dispensed for each button panel.
To enter dose programming you have to press button
(5) for 10 seconds, the button blinks, the other buttons
go out and the following screen appears on the display
to indicate entry into dose programming:
Doses Setting
Select Withing 30s

9.1 - PROGRAMMING COFFEE DOSES

NOTE:
Programming is done on the first keyboard on the left
and is automatically shown on the other keyboards of
the groups in the machine.
You can change the programming of the doses of
groups 2 or 3 by repeating the same operation as
done for group 1.
Entering the programming phase as already
described the following screen appears:
Doses Setting
Select Withing 30s
Within 30 seconds press button (1), coffee
dispensing starts, when the desired quantity of
coffee is reached press button (1) again, it lights
steadily to indicate that the quantity of coffee
dispensed has been stored.
Repeat the operations described in the preceding
paragraphs also for buttons (2), (3) and (4) and
when programming is finished press button (5)
twice, or you exit automatically after 30 seconds.

9.2 - PROGRAMMING WATER DOSE

ENGLISH / 16
Place a cup under the hot-water wand.
Entering the programming phase as already
described, the following screen appears:
Doses Setting
Select Withing 30s
Press button (6) within 30 seconds, water dispensing
starts, when the desired quantity of water is reached
press button (6) again, then press button (5) twice,
or you exit automatically after 30 seconds.

9.3 - READING THE COUNTERS

The machine's logic makes it possible to store;
The litres dispensed;
The total number of dispensings done;
The quantity of dispensings done for each button.
To enter the counter reading phase you have to enter
user programming, as already described, the following
screen appears:
Doses Setting
Select Withing 30s
Press button (5) and the following screen
appears:
Counters
Press button (3), the following screen appears:
Litres
XXXXX