Setting The Manual Mode - DeDietrich MCR 24, MCR 24/28MI, MCR 30/35MI, MCR 34/39MI Manual

Wall-hung gas condensation boilers
Hide thumbs Also See for MCR 24, MCR 24/28MI, MCR 30/35MI, MCR 34/39MI:
Table of Contents

Advertisement

Parameter
Description
Flow temperature T
P1
DHW T
P2
set
P3
Boiler regulation
P4
Energy-saving mode
P5
Anticipation resistance
The screen goes off
P6
automatically

3 Setting the manual mode

8
20 to 85 °C
set
40 to 65 °C
0 = Heating programme deactivated, DHW programme
deactivated
1 = Heating programme activated, DHW programme
active
2 = Heating programme activated, DHW programme
deactivated
3 = Heating programme deactivated, DHW programme
active
0 = Comfort
1 = Energy-saving mode
2 = Regulation operated by the controller
0 = No anticipation resistance for the ON/OFF thermostat
1 = Anticipation resistance for the ON/OFF thermostat
0 = The screen stays off
1 = The screen stays on
2 = The screen goes off automatically (After 3 minutes)
MCR 24, 24/28MI, 30/35MI, 34/39MI
Comments
- Press key
several times until the symbol
menu bar.
- Press the
key. The minimum outlet temperature P1 or the text
Auto is displayed if an outside temperature sensor is installed.
- Press the + key to increase the outlet temperture manually.
- To confirm, press the
The installation is in manual mode.
- Press key
1 time to deactivate the manual mode.
- Press key
1 time to return to the current operating mode.
Factory setting
24
24/28MI
30/35MI
75 °C
55 °C
2
1
1
2
0
2
flashes on the
key.
08/06/06 - 300008487-001-A
34/39MI
1