Notes On Locations; Indoor Unit; Outdoor Unit; Piping - Electrolux EXH09HX Installation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

Items
8
Cord holder
9
Manuals
10
Air purifying filter

Notes on locations

Important! Keep the following points in mind
and get the customer's approval.

Indoor unit

1. Keep the air outlet clear of any obstacle
so that outgoing air flows smoothly in the
entire room.
2. Make a drain hose hole for easy drainage.
3. Provide sufficient space on both sides
and above the unit.
4. The air filters should be easily taken in and
out.
5. Keep TV set, radio and the like 1 m or
more away from the unit and the remote
control.
6. Keep the air inlet clear of obstacles that
could block incoming air.
7. The remote control may not function
properly in a room equipped with an elec-
tronic simultaneous-start or rapid-start
fluorescent lighting.
8. Select a location that does not cause loud
operation noise and extreme vibrations.

Outdoor unit

1. Place the outdoor unit on a stable base.
2. Provided sufficient space around the
unit. It should also be well ventilated.
3. The unit should not be exposed to strong
wind nor splashed with rain water.
4. Water drain from the unit should be let
out without problem. Lay a drain hose if
required. In cold regions, installation of
the drain pipe is not advisable as freezing
could result.
5. Keep TV set, radio and the like 1 m or
more away from the unit.
6. Avoid locations exposed to machine oil
vapor, salty air (facing the seashore, for
example), hot spring vapor sulfur gas,
Q'ty
1
To secure the electrical cable.
1
Installation manual
1
Operation manual
2
To remove dust and tobacco smoke from the air.
7. Also, avoid locations exposed to muddy
8. Select a location where the outgoing air
9. Install the unit on a stable base not to al-
10. Keep the air outlet opening free of any

Piping

1. Piping length should be 1m or more in
2. If piping length exceeds 10m, add 20g of
3. When the outdoor unit is placed at a high-
A) Max. piping length 15m
B) Max. level difference 7m
1
2
3
Application
etc. Such location can cause break-
down.
water (along a road, for example) or
where the unit can be tampered with.
or operating noise cannot annoy others.
low louder noise.
obstacle. This could affect the perform-
ance of the unit and create loud noises.
order to decrease vibration propagated
from the outdoor unit.
refrigerant per 1m.
er level than the indoor units, provide a
trap near the hose's lead-in port.
1
A
B
2
Indoor unit
Outdoor unit
Trap
electrolux 3
B
3