Download Print this page

Technical Specifications - Siemens SINAMICS G120P Operating Instructions Manual

Du/dt fillter plus voltage peak limiter
Hide thumbs Also See for SINAMICS G120P:

Advertisement

Technical specifications

General technical data
Table 6- 1
General technical data
Product standard
Specific technical data
Table 6- 2
Technical specifications for the du/dt filter plus Voltage Peak Limiter, 380 V – 480 V 3 AC
Order number
I
thmax
Degree of protection
du/dt reactor
Power loss
- at 50 Hz
- at 60 Hz
Connections
- to the Power Module
- Load
- PE
Max. permissible cable
length between du/dt reactor
and motor
Dimensions
Width
Height
Depth
Weight, approx.
Voltage peak limiter
Power loss
- at 50 Hz
- at 60 Hz
Connections
- to the du/dt reactor
- DC
- PE
Dimensions
Width
Height
Depth
Weight, approx.
dV/dt filter plus Voltage Peak Limiter
Operating Instructions, 04/2014, A5E32847105B AB
EN 61800-5-1
6SL3000-
2DE35-0AA0
A
490
IP00
kW
0.874
kW
0.904
M12
M12
M6
m
mm
460
mm
370
mm
275
kg
122
kW
0.042
kW
0.039
Terminal 70 mm²
Terminal 70 mm²
Terminal 35 mm²
mm
392
mm
285
mm
210
kg
16
2DE38-4AA0
840
IP00
1.106
1.115
M12
M12
M6
300 (shielded)
450 (unshielded)
460
385
2031
149
0.077
0.072
M8
M8
M8
309
1312.5
400
48
6
25

Hide quick links: