Remote Access via Dialup Modem: 
 
1. Setup the System 
Install CD‐VM21 daughter board onto the CD‐CP00 blade. 
Assign PSTN DIL or ISDN DID to modem number (PRG 11‐15‐14, Default = 740). 
On PC, install and configure modem with a connection to the PSTN. 
 
2. Create a PPP Dialup Connection Account (one per destination) 
Access Network Connections via Windows Control Panel. 
Select " File " and "New Connection" 
Select " Connect to Network at my Work place " 
Select Dial up connection. 
Add Name for PPP setup. 
Add Phone number for dial up connection destination. 
Allow access rights, e.g. Anyone's use. 
Click Next. 
Click Finish. 
 
3. Connect using PCPro 
Select Communications, Connect... 
Under Connection Type, select Dial‐up. The IP address is fixed for the system. 
Under Login, specify User Name, e.g. tech and Password, e.g. 12345678. 
Select Connect. 
From the Network Connections window that appears, select your PPP Dialup Connection Account 
for the appropriate SV8100 destination. 
Select Connect. 
From the Connect window that appears, select Dial. 
PCPro will now dialup and connect via the PPP account. 
When the PCPro connection is terminated the PPP dial up connection will also be terminated and 
the line dropped. 
 
Document No. SIB 244
NEC Australia Pty Ltd shall not be liable for any direct, indirect, consequential or incidental damages about the use of the information included in this document.
The information in this technical documentation is advisory in nature and is subject to change. NEC may make improvements and changes in the products
described in this documentation without notice. Contents of this document are subject to change without prior notice at the discretion of NEC Australia Pty Ltd.
This document has been prepared for use by employees and dealers of NEC Australia Pty Ltd and may not be reproduced without prior written approval of NEC
Australia Pty Ltd.