2. Safety Information 
To ensure the safe operation and service of the meter, follow these instructions closely. Failure to 
observe warnings can result in severe injury. 
 
WARNINGS 
WARNINGS identify hazardous conditions and actions that could cause BODILY HARM or DEATH. 
When handling test leads or probes, keep hands and fingers behind the finger guards at all times. 
Remove test leads from the meter before opening the battery compartment or meter housing. 
Use the meter only as specified in this User Guide or accompanying Quick Start to avoid compromising 
the protections provided by the meter. 
Be sure to use the proper terminals, switch positions, and ranges when taking measurements. 
Verify the meter's operation by measuring a known voltage. Have the meter serviced if the meter 
responds unusually or if there are questions regarding the meter's functional integrity. 
Do not apply more than the rated voltage, as marked on the meter, between terminals or between any 
terminal and earth ground. 
Replace blown fuses with fuses of the same type and rating as specified in this User Guide. 
Use caution working with voltages above 30 VAC RMS, 42 VAC peak, or 60 VDC. These voltages pose a 
shock hazard. 
To avoid misleading readings that could lead to electric shock and injury, replace the batteries as soon as 
the low battery indicator is displayed. 
Disconnect power to the circuit under test and discharge all high‐voltage capacitors before testing 
resistance, continuity, diodes, or capacitance. 
Do not use the meter in the presence of explosive gas or vapor. 
To reduce risk of fire or electric shock, do not use the meter if it is wet and do not expose the meter to 
moisture. 
Individual protective equipment should be used if HAZARDOUS LIVE parts in the installation where 
measurements are to be carried out could be accessible. 
 
CAUTIONS 
CAUTIONS identify conditions and actions that could cause DAMAGE to the meter or equipment 
under test. Do not expose the meter to extremes in temperature or high humidity. 
Disconnect the test leads from the test points before changing the position of the function (rotary) 
switch. 
Do not expose the meter to extremes in temperature or to high humidity. 
Never set the meter to the resistance, diode, capacitance, or amp functions when measuring the 
voltage of a power supply circuit; this could result in meter damage and damage to the equipment 
under test. 