Resistance Measurements 
Cautions: Switch OFF power to the device under test before measuring. Do not test on circuits 
or devices where 60VDC or 30VAC is present. 
1.
Insert the black test lead banana plug into the negative (COM) jack. Insert the red test 
lead banana plug into the positive (V/Ω) jack. 
2.
Turn the Function Switch to the Ω position. 
3.
Use the M button to select the Ω icon on the display indicating resistance only (without 
the audible continuity icon showing).  
4.
The meter defaults to the Auto Range mode (Auto displayed on LCD). Press the R button 
to access the manual range mode. Press the R button to step through the ranges. Press 
and Hold the R button to return to the Auto Range mode (Auto will be displayed). 
5.
Touch the test probe tips across the circuit or part under test. It is best to disconnect one 
side of the part under test so the rest of the circuit will not interfere with the resistance 
reading. 
6.
Read the resistance value in the display. The display will indicate the proper decimal 
point and value. If the reading is out of range, the OL display icon will appear. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fig 4‐6 RESISTANCE/CONTINUITY MEASUREMENTS
 