Fixing the Installation Plate
The design and shape are subject to change
according to the model.
Installation plate
Pipe hole
(
Ø
65mm)
AVXWH028/036
(Unit : mm)
��
���
AVXWH045/056/071
(Unit : mm)
���
���
AVXWP022/028
(Unit : mm)
AVXWP036/045
(Unit : mm)
AVXWP056/071
(Unit : mm)
���
���
10
E-
Before fixing the installation plate to a wall or window frame, you must
determine the position of the 65-mm hole through which the cable, piping and
hose pass to connect the indoor unit up to the unit.
When facing the air conditioner in position on the wall, the piping and cable can
be connected from the:
1
Determine the position of the pipe and drain hose hole using the right figure
and drill the hole with an inner diameter of 65-mm so that it slants slightly
downwards.
2
If you are fixing the indoor unit to a...
Wall
Window frame
��
3
Fix the installation plate to the wall in a manner appropriate to the weight of
the indoor unit.
Note
��
4
Determine the positions of the wooden uprights to be attached to the
window frame.
5
Attach the wooden uprights to the window frame in a manner appropriate to
the weight of the indoor unit.
6
Using tapped screws, attach the installation plate to the wooden uprights, as
illustrated in the last figure opposite.
Right
Left
Rear (right or left)
Underside
If you are mounting the plate on a concrete wall with anchor bolts,
the anchor bolts must not project by more than 20 mm.
Then follow Steps...
3.