Connect the battery charger
Connect the battery charger to the voltage and
frequency specified on the rating plate. Put the
electric plug in a earthed socket-outlet. The LED on
the battery charger flashes green once. (4)
Connect the battery to the battery charger
The battery must be charged before using it the first time.
The battery is only 30% charged when delivered.
Put the battery in the battery charger. Make sure that
the battery is connected to the battery charger. (1), (2)
The green charging light on the charger is lit when the
battery is connected to the battery charger. The
battery will not be charged if the battery temperature
is over 50 ° C. In that case the battery charger will
actively cool down the battery. (4)
When all LEDs are lit the battery is fully charged. (7)
Remove the battery from the battery charger.
Pull out the plug. Never jerk the power supply cable to
disconnect it from the wall socket. (3)

Transport and storage

Store the equipment in a lockable area so that it is out
of reach of children and unauthorized persons.
Store the battery and the battery charger in a dry,
moisture-free and frost-free space.
Store the battery and the battery charger where the
temperature is between 5 °C and 45 °C and never in
direct sunlight.
Store the battery charger only in an enclosed and dry
space.
Be sure to store the battery separate from the battery
charger.

Maintenance

Make sure the battery and battery charger are clean and
that the terminals on the battery and the battery charger
are always clean and dry before the battery is placed in
the battery charger.
Keep the battery guide tracks clean. Clean plastic parts
with a clean and dry cloth.
Fault codes
Troubleshooting the battery and/or the battery charger
during charging.
(5), (6)
Possible
LED display
faults
Error LED
Temperature
flashing
deviation
Cell difference
Error LED is lit
too much (1V)
4 – English

BATTERY HANDLING

Possible action
Use the battery in
surroundings where
temperatures are
between -10 °C and
40 °C.
Contact your service
agent.
If the LED on the battery charger is lit solid red, the
battery charger requires a service. (5)
Disposal of the battery, battery charger
and machine
Symbols on the product or its packaging indicate that this
product cannot be handled as domestic waste. It must
instead be submitted to an appropriate recycling station
for the recovery of electrical and electronic equipment.
By ensuring that this product is taken care of correctly,
you can help to counteract the potential negative impact
on the environment and people that can otherwise result
through the incorrect waste management of this product.
For more detailed information about recycling this
product, contact your municipality, your domestic waste
service or the shop from where you purchased the
product.

Technical data

Technical data
Battery charger
Mains Voltage, V
Frequency, Hz
Power,W
EC Declaration of Conformity
(Applies to Europe only)
Husqvarna AB, SE-561 82 Huskvarna, Sweden, tel: +46-
36-146500, declares under sole responsibility that the
battery chargers, Husqvarna Quick charger 120 and
Quick charger 330 from 2011's serial numbers and
onwards (the year is clearly stated in plain text on the
rating plate with subsequent serial number), are in
conformity with the requirements of the COUNCIL'S
DIRECTIVES
- of December 15, 2004 "relating to electromagnetic
compatibility" 2004/108/EC.
The following standards have been applied: EN 60335-1
EN 60335-2-29 Conformity assessment according to
Annex V.
Huskvarna, 31 October 2011
Peter Lameli, CTO
QC120
QC330
220-240
100-240
60
50-60
125