7. Troubleshooting

Cleaning the Pump :
E
F
Fault
No water feature operating
Reduced water feature
Pump shuts down after
a short time
In the event of other faults please contact GARDENA Service.
Repairs should only be carried out by GARDENA service centres or dealers
A
authorised by GARDENA.
8. Accessories
GARDENA
Underwater lights
GARDENA
radio control set
DANGER ! Electric shock !
A
V Disconnect the mains plug of the pump before
carrying out maintenance work !
1. Remove the pump from the filter housing (see 6. Maintenance).
2. Turn the pump housing
off the motor housing
D
3. Pull the impeller
4. Push the cleaned impeller
5. Press the pump housing
and turn it clockwise. (Bayonet fastening).
6. Reassemble the pump into the filter housing (see
6. Maintenance).
Possible cause
Mains plug not plugged in.
Regulating valves are closed.
Water bell or fleur-de-lis screwed v Unscrew water bell or fleur-
too far into the nozzle tube.
Impeller unit is blocked.
Water feature insert is dirty.
Filter housing / filter bowls dirty.
Water temperature too high.
Illuminate water features and
the edges of the pond.
Start water features and lighting
from the terrace or your living
room.
D
anticlockwise and pull it vertically
E
(Bayonet fastening).
F
out of the motor housing
F
back into the motor housing
D
vertically on to the motor housing
Remedy
v Plug in mains plug.
v Open regulating valves.
de-lis slightly out of the
nozzle tube.
v Clean pump.
v Clean water feature insert
and nozzle pipe.
v Clean filter housing / filter
bowls.
v Maximum water
temperature is 35 °C.