Gardena 4000/4 LCD Operating Instructions Manual

Gardena 4000/4 LCD Operating Instructions Manual

Electronic pressure pump

Advertisement

D
Betriebsanleitung
Hauswasserautomat
GB
Operating Instructions
Electronic Pressure Pump
F
Mode d'emploi
Station de pompage
NL
Instructies voor gebruik
Hydrofoorpomp
S
Bruksanvisning
Pumpautomat
I
Istruzioni per l'uso
Pompa ad intervento automatico
E
Manual de uso
Estación de Bombeo
P
Instruções de utilização
Bomba de Pressão
DK
Brugsanvisning
Husvandværk
4000/4 LCD
4000/5 LCD
5000/5 LCD
6000/5 Inox LCD Art. 1769
Art. 1763
Art. 1765
Art. 1767

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4000/4 LCD and is the answer not in the manual?

Questions and answers

Summary of Contents for Gardena 4000/4 LCD

  • Page 1 4000/4 LCD Art. 1763 4000/5 LCD Art. 1765 5000/5 LCD Art. 1767 6000/5 Inox LCD Art. 1769 Betriebsanleitung Hauswasserautomat Operating Instructions Electronic Pressure Pump Mode d’emploi Station de pompage Instructies voor gebruik Hydrofoorpomp Bruksanvisning Pumpautomat Istruzioni per l’uso Pompa ad intervento automatico Manual de uso Estación de Bombeo...
  • Page 2: Table Of Contents

    The in creased delivery pressure and the pump pressure have to be added together. • Example: pressure at the tap = 1.5 bar, maximum pressure of the Pressure Tank Unit 4000/4 LCD = 4.4 bar, total pressure = 5.9 bar. Liquids that can be pumped: The GARDENA Electronic Pressure Pump can be used for pumping rainwater, tap water and chlorinated swimming pool water.
  • Page 3: Safety Instructions

    0100-738 use of the pump near to swimming ➔ In case of damage, please have the pump pools and garden ponds and other similar checked by our GARDENA Service Centre places is only permissible if the pump is or by an authorised electrician.
  • Page 4 Electronic control display ³ Power ON display: The pump is connected to the mains. Pump ON display: The pump is pumping. Manual display: Only displayed in manual operation. l/h or bar display: Indicates whether throughput or pressure is being displayed. Frost symbol: The temperature in the pump was or is below 3 °C.
  • Page 5: Using The Equipment For The First Time

    (e.g. by fastening it to a wooden post). This relieves the pump of the weight of the suction hose. If very fine dirt is present, we recommend the use of a GARDENA pump preliminary filter art. 1730 / 1731 in addition to the integrated filter.
  • Page 6: Operation

    19 mm (3/4“) diameter, art. no. 4432 / 8452, in conjunction with the GARDENA fast connection threaded connector with a 33.3 mm (G1) internal thread art. no. 7109 and the GARDENA suction and high pressure connector, art. no. 7120, for 19 mm (3/4“) hoses and a GARDENA hose clamp art.
  • Page 7 In some circumstances ERROR 06 may appear. This does not impair the further operation of the pump. 8. When the pump has drawn in the water, turn the rotary switch to RUN. 9. Close shut-off devices in the delivery pipeline again. The pump switches off automatically when the maximum Normal mode pressure is reached.
  • Page 8: Preparation For Storage

    6. Preparation for Storage Winter storage / out of use: Empty the Electronic Pressure Pump before the first frost. 1. Unplug the pump from the mains. 2. Turn rotary switch to .START. 3. Unscrew drain bolt © The pump will be drained. 4.
  • Page 9: Troubleshooting / Service

    ➜ Ensure compliance with maximum temperature of the delivery medium (35 °C). ➜ Ensure the pump is located in a well-ventilated area. ➜ Contact GARDENA Service. Interruption to power supply. ➜ The function continues to Direct sunlight (Display temperature > 65 °C).
  • Page 10 ➜ Check outlet and all hose Seal failed on the output side (leak). and accessories connected to it for leaks. ➜ Contact GARDENA Service. Deposits of dirt on the impeller of the dry-running safety device. ➜ Increase throughput. Throughput was < 140 l/h for several minutes.
  • Page 11 Manual remaining is shown in minutes (10). flashes 3. Press shift and manual key again simultaneously. Manual operation is discontinued prematurely. Pressing the reset key returns the system to normal mode. If any other faults occur, please contact GARDENA Service.
  • Page 12: Accessories Available

    Kink- and vacuum-resistant, sold by the metre with 19 mm (3/4”) or 25 mm (1”) diameter without fittings or in fixed length, complete with fittings. GARDENA Suction Hose Fittings • Art. no. 1723/1724 GARDENA Suction Filter To equip suction hoses with •...
  • Page 13: Warranty

    11. Warranty GARDENA guarantees this product for 2 years (from date of purchase). This guarantee covers all serious defects of the unit that can be proved to be material or manufacturing faults. Under warranty we will either replace the unit or repair it free of charge if the following conditions apply: •...
  • Page 14 GARDENA, ou pe- ças não autorizadas. A responsabilidade tornar-se-à nula também depois de reparações realizadas por oficinas não autorizadas pela GARDENA.
  • Page 15 énoncées ci-après et conforme aux règles de sécurité et autres règles qui EU-Richtlinien: 98/37/EG : 1998 lui sont applicables dans le cadre de l’Union européenne. Toute modification EU directives: portée sur ce produit sans l’accord express de GARDENA supprime la validité 2006/42/EG : 2006 Directives européennes : de ce certificat. EU-richtlijnen:...
  • Page 16 Pumpen-Kennlinie: Performance characteristics Courbes de performance Prestatiegrafiek Pumpens kännetecken Curva di rendimento Curva característica de la bomba 1000 2000 3000 4000 5000 6000 l / h Características Die Leistungsdaten der Pumpenkennlinie sind gemessen bei einer de performance Saughöhe von 0,5 m und unter Verwendung eines 25 mm (1”)- Saugschlauchs.
  • Page 17 Case Postale No. 12 Phone: 1800 658 276 Luxembourg 2010 spare.parts@nylex.com.au Slovenia Denmark Phone +352-40 14 01 GARDENA d.o.o., Brodišče 15, 1236 Trzin Austria/Österreich GARDENA Norden AB api@neuberg.lu Phone: (+386) 1 580 93 32 GARDENA Österreich Ges.m.b.H. Box 9003, 200 39 Malmö, Sverige servis@gardena.si...