16 Configuring the network settings [Network]
When the [Confirm] button is clicked, the registered information of the installed server certificate
will be displayed in the "CA Certificate - Confirm" dialog box. (Only "Organizational Unit" will be
displayed with an asterisk (*).)
When the [Delete] button is clicked, the installed server certificate will be deleted.
When "HTTPS" is selected for "Connection", it is impossible to delete the server certificate.
To change (or update) the server certificate, perform step 1 and 2.
IMPORTANT
Before deleting the valid server certificate (security certificate), confirm that there is a backup file on
the PC or another media. The backup file will be required when installing the server certificate again.
When the server certificate has expired, the HTTPS function will become unavailable. When the
camera is restarted, the connection protocol will be changed to HTTP. Update the server certificate
before it expires.
The expiration date of the server certificate can be checked by double-clicking the server certification
file issued by CA.

16.3.5 Configuration of the connection protocol

1.
Select "HTTP" or "HTTPS" for "Connection" to determine the protocol used to access the camera.
HTTP: Only the HTTP connection is available.
HTTPS: Only the HTTPS connection is available.
2.
Designate the HTTPS port number to be used for "HTTPS port".
Available port number: 1 - 65535
Default: 443
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 554, 995, 10669, 10670, 59000 - 61000
3.
Click the [Set] button.
It will become possible to access to the cameras using the HTTPS protocol. (®page 8, page 18,
page 20)
Note
When the connection setting is changed, after waiting for a while, access the camera again with either
"http://IP address of the camera" or "https://IP address of the camera" depending on the changed
setting.
When using the self-signed certificate: